Instructions

5.USE OF THE DEVICE
Output voltage and current limit
Press V/↑ to open the voltage setting mode. Press the rotary switch to set
the cursor on the numerical value which should be changed. Rotate the
rotary switch clockwise to increase the value and counter clockwise to
decrease the value. Press again V/↑ to end. Alternatively, aer 30 seconds
of being inactive the setting mode ends automatically. Press A/↓ to set the
output current limit the same ways as before.
Conguration of data and conservation values
Press SET in the main screen to open the data settings menu.
Setting the voltage and current limit values
Navigate through the menu to option U-SET (voltage limit) or I-SET (current
limit). Adjust here the output voltage and / or the output current limit aer
your preferences. With SET can you go back to the menu options. Press SET
again to return to the main screen and to leave the menu.
Setting the conservation value
Navigate through the menu to limit value options S-OVP (overvoltage
protection), S-OCP (overcurrent protection) or S-OPP (overpower
protection). Adjust now with the rotary switch the desired value. Press
SET to return to the menu options and again to leave the menu. If the limit
values are reached, the output will be deactivated automatically.
Attention! These are global limit values and should not be
confused with the default voltages and currents.
Adjustment of screen brightness
Navigate to the option B-LED to congurate the screen brightness. Rotate
the rotary switch to adjust the brightness from level 0 to 5. 0 denes the
darkest level and 5 the brightest. Press SET to return to the menu and press
it again to leave the menu.