Wood stove F 3 Operating Instructions
&
WALL SHIELD
•
Must be 30” wide and
centered
behind the
stove
•
Must be 1” off the wall
and 1” off the floor.
•
With standard legs, the
shield must be 32” high.
•
With optional short legs,
the shield must be 30”
high.
&20%867,% /(
:$//
WALL SHIELD
•
Must be 1” off the wall
and 1” off the floor.
•
With standard legs, the
shield must be 40” high.
•
With optional short legs,
the shield must be 38”
high.
•
Both shields MUST
extend and join in the
corner
The wall shield must extend a
mini mu m of 4” (102mm) past the
ash lip of the stove.
The wall shield must extend a
minimum of 4” (1 02 mm) p ast
the side of the stove.
The wall shield must
extend a minimum of
12” (305mm) past the
front corner of the stove.
&20%867,% /(
:
WALL SHIELD
•
Must be 1” off the wall
and 1” off the floor.
•
With standard legs, the
shield must be 40” high
•
With the optional short
legs, the shield must be
38” high.
•
Both shields must
extend and join in the
corner.
The wall shield must
extend a minimum of 12” (305mm)
past the front c orner of the stove.
WALL SHIELDS FOR CLOSE CLEARANCE
COMBUSTIBLE
WALL
12
WALL