7.2 HYDROSTATIC RELEASE REPLACEMENT
WARNING
Only Jotron approved hydrostatic release is acceptable for use
7.2.1 REPLACING THE RELEASE MECHANISM IN FB-40 BRACKET
1. Release and remove FB-40 top cover by removing the cotter pin (1).
WARNING! The EPIRB can drop out of the FB-40 bracket when releasing the
top cover. Remove the EPIRB from the bracket.
2. Press down the spring-loaded bracket plate and remove the hydrostatic unit
by sliding it out of its locking slot (4)
3. Check the expiry date of the new hydrostatic release mechanism. The date
should be approximately two years from the date of purchase.
4. Install a new hydrostatic unit by pressing down the spring loaded bracket
plate and sliding the unit into its locking slot (5).
5. Refit the EPIRB and the FB-40 top cover (6-7).
6. First fit the cover from the top. Mount the cutter pin then press firmly at the
bottom back cover while pressing the cover down. A “snap” sound can be
heard when the snap-lock enters (8-9).