Instructions / Assembly
EZSR-23
FIBER SLIT & RING TOOLS
FOR EZ!FUSE
™
SC & LC
SPLICE-ON CONNECTORS
INSTRUCTION MANUAL
3
4. Insert the cable into the ringing slot with the ‘6’ marking aligned until the jacket of the cable
banks against the wall of the black dial again.
(3)
5. Close the tool and ring another 6 mm of jacket off the cable, leaving 6 mm of aramid yarn
and 26 mm of tight buffer exposed.
6. Next, open the tool and insert the cable into the slitting slot until the jacket banks against the
blue wall of the slitting slot.
(4)
7. Finally, close the tool and pull the cable towards you, slitting 19 mm of cable jacket.
(5)
8. Insert the tight buffer into the groove on the side of the tool (marked with “23 mm”) and
mark it with a marker.
9. Using a separate stripping tool, like the JIC-375, strip off 23 mm of tight buffer and 23 mm
of the secondary coating of the fiber cable afterwards.
10. Fold back the outer jacket and load the bare fiber into the separate fiber holder by clamping
it down as close to the jacket as possible.
11. With the fiber holder closed, align the exposed fiber with the 7 mm marking of the EZSR-23
to ensure it is the proper 7 mm length.
12. The fiber cable is now ready to be cleaved and used with an EZ!Fuze™ LC Splice-On
Connector
(3)
(4)
(5)