User Manual

www.joinwit.com
2
iiTechnical Specifications
Instrument model
parameters
JW3209A
JW3209C
Power meter
Calibration
wavelength(nm)
8501300 1310149015501625
Testing range(dBm)
-70+6
-50+26
Display resolution(dB)
0.01
Uncertainty(dB)
≤±0.25
linearity(dB)
≤±0.1
Frequency indentification
range
10K
Source
Working wavelenghtnm
1310/1550(customizable)
Typical Output Power(dBm)
-5(customizable)
StabilitydB,30min,20℃
0.1dB
Modulation frequency (Hz)
CW,270Hz1KHz2KHz
Other parts
Power supply
3*AA 1.5Vbattery / Mini USB 5Vadapter
Auto-off time (min)
10
Battery continuous
operation time
)
(h)
Source ON50,source off200
Communication Interface
Mini USB
Working temperature
-10+60
Storage temperature
-25+70
size(mm)
175×90×44.5
weight(gnot including
battery)
265
Notes650 optional red light mode
: Tested in T=23±2
: Battery operating time is tested when the backlight is off, otherwise the working
time will be shorter