Instruction Manual

WWW.JOHNSONSYSTEMS.COM
6
Installation
J-Pack Series dimmer packs are intended for indoor use only, in a controlled environment at a room
temperature.
Mount in a suitable location.
Refer to the Mounting Options section on page 6 for applicable details.
Connect the applicable AC power supply input.
Refer to the AC Power Supply Input Options section on page 8 for applicable details.
Connect the relay output receptacles/terminals.
Refer to the Relay Output Connection Options section on page 10 for applicable details.
Connect DMX and/or dry contact control input(s).
Refer to the Control Input section on page 12 for details.
Program, setup, test and verify functionality.
Refer to the Detailed Programming of System Conguration Menu Items section
on page 18 for details.
WARNING: For indoor use only!
Mounting Options
J-PACK Series dimmer packs are capable of various mounting options to suit the application required.
A cooling fan mounted inside the dimmer pack is used to move air through the chassis and cool
the heat sink and chokes. The fan is temperature controlled via a temperature sensor mounted on
the heat sink. If the heat sink temperature is >=55ºC the fan is turned on to half speed. If the heat
sink temperature is >=70ºC the fan is turned full on. It is important to mount the dimmer pack in the
orientation intended with unobstructed ventilation to ensure adequate cooling.
RF = Rubber Feet
For portable applications, the dimmer pack
can be set on any at surface. Rubber feet are
mounted on the bottom of the dimmer pack,
with indents on the top cover panel to facilitate
vertical stacking of up to 6 units high.
WARNING: Never place the dimmer packs
side by side (horizontally) without
a minimum of 12" of clearance
between them. Always leave a
minimum of 6" of clearance from
the dimmer packs air intake and
exhaust. Failure to comply may
cause thermal overheating.