User Manual
www.johnsonsystems.com 29
K:XXXXXX Shows the unique six-character hard-key code (XXXXXX).
K:XXXXXX Follow the procedure below to enter the menu and modify the hard-key.
K:XXXXXX Press and hold EXECUTE and then ESCAPE at the same time for 4-5 seconds.
K>XXXXXX A pointer (>) appears to indicate hard-key modication is activated.
K>XXXXXX Press MENU ( ) to modify the rst hard-key character.
K:>XXXXX Press EXECUTE to advance to the second hard-key character.
K:>XXXXX Press MENU ( ) to modify the second hard-key character.
K:X>XXXX Press EXECUTE to advance to the third hard-key character.
K:X>XXXX Press MENU ( ) to modify the third hard-key character.
K:XX>XXX Press EXECUTE to advance to the fourth hard-key character.
K:XX>XXX Press MENU ( ) to modify the fourth hard-key character.
K:XXX>XX Press EXECUTE to advance to the fth hard-key character.
K:XXX>XX Press MENU ( ) to modify the fth hard-key character.
K:XXXX>X Press EXECUTE to advance to the sixth hard-key character.
K:XXXX>X Press MENU ( ) to modify the sixth hard-key character.
Press ESCAPE to exit the menu and save the desired hard-key code.
Press RESET to exit the menu without saving.
The menu will automatically timeout after 5 minutes of inactivity and save.
NOTE: Be sure to record and le the hard-key code on page 33 for future reference.
38. SERIAL# View the microcontroller’s unique six-character silicone serial number.
XXXXXX Shows the unique six-character serial number.
39. VERSION View the microcontroller’s software version.
VER X.X Shows the microcontroller’s software version.
40. EEPROM View the type of EEPROM memory module plugged in.
All EDI-120 retrot control systems come equipped with a removable EEPROM
memory module located at the rear of the EDI-120 chassis. The EEPROM memory
module inserts into the on-board connector, and may be removed for safe storage.
The EEPROM type is programmed for parameter (P) or rmware (F) operation. A
parameter EEPROM is used to backup all of the current conguration settings. A
rmware EEPROM is used to update the current rmware version running on the EDI-
120 microcontroller to the rmware version saved on the EEPROM.
The EEPROM memory module supplied with all EDI-120 retrot control systems is
a parameter type with all of the factory default conguration settings saved onto it
before shipping.
EDI120-P Indicates the EEPROM memory module is for an EDI-120 microcontroller.
EDI120-P Indicates the EEPROM type is programmed for parameter (P) operation.
XXXXXX Press EXECUTE to display the silicone serial number parameter.
DISABLED Press EXECUTE and this menu feature is disabled for factory use only.
EDI120-F Indicates the EEPROM type is programmed for rmware (F) operation.
VER X.X Press EXECUTE to display the version (VER) of the rmware.
DISABLED Press EXECUTE and this menu feature is disabled for factory use only.
NONE! Indicates the EEPROM memory module is not installed.
41. FW-LOAD Load new rmware into the EDI-120 via the EEPROM memory module.
If a rmware update is required, Johnson Systems Inc. may supply an EEPROM
memory module with the latest rmware version. The rmware EEPROM memory
module can be inserted into the on-board connector located at the rear of the EDI-120
chassis, and the rmware can be loaded into the microcontroller.
Press EXECUTE to enter the menu.
DISABLED This menu is disabled to help prevent inadvertent changes. Proceed to enable.
ENABLED Press and hold MENU ( ) and MENU ( ) at the same time for 4-5 seconds.