User Manual
www.johnsonsystems.com
26
25. TEST INC Set the test increment units to percent or hexadecimal.
The levels for the dimmer test (DIM TEST) and analog test (ANA TEST) features can
be displayed as a percentage or hexadecimal value.
PERCENT Press EXECUTE to toggle test increments from PERCENT to HEX VAL.
HEX VAL Press EXECUTE to toggle test increments from HEX VAL to PERCENT.
Any change in the conguration is automatically saved.
26. OC MODE Congure the input trigger parameters for the open collector output.
The on-board open collector output is used to sink up to 100mA of current. It can be
congured to be triggered via a selected DMX channel, analog input 4, or both. The
open collector is triggered on at 55% control input and triggered off again at 45%
control input. When analog and DMX (A+D) is selected to trigger the open collector
the inputs are combine for highest takes precedence (HTP).
Press EXECUTE to enter the menu and congure the open collector output.
A+D< 001 Displays the active trigger mode as analog and DMX (A+D<) channel (001).
A+D> 001 Press EXECUTE to toggle the pointer (>) and select the DMX channel.
A+D> 512 Press MENU ( ) to change and select the DMX channel from 001 to 512.
A+D< 512 Press EXECUTE to toggle the pointer (<) and select a different trigger mode.
DMX< 512 Press MENU ( ) to select DMX input trigger mode.
ANA< Press MENU ( ) to select analog (ANA) input trigger mode.
OFF< Press MENU ( ) to deactivate (OFF) the open collector output.
Press ESCAPE to exit the menu and save the desired settings.
Press RESET to exit the menu without saving.
The menu will automatically timeout after 5 minutes of inactivity and save.
27. AUX IN Select which scene the auxiliary input will trigger/enable.
When a contact is sensed on the auxiliary input the selected scene will be triggered
and held until the contact is removed. The auxiliary input only functions when scene
mode (SCENESET) is activated or when the systems scene mode (SCENEMOD) is
enabled and active.
SCENE:01 Displays the scene (01) that will be triggered by the auxiliary input.
SCENE>01 Press EXECUTE to enter the menu and select a different scene.
SCENE>12 Press MENU ( ) to change the selected scene from 01 to 12.
Press ESCAPE to exit the menu and save the desired scene to be triggered.
Press RESET to exit the menu without saving.
The menu will automatically timeout after 5 minutes of inactivity and save.
28. SCENEMOD Enable or disable scene mode and the auxiliary input.
Enabling scene mode puts the system in scene mode. With scene mode enabled
the selected scene will always be activated when DMX is not being received. The
selected scene can be changed in the SCENESET menu. Scene mode enables the
use of the auxiliary input. A contact closure sensed on the over-temperature, re
alarm or security alarm inputs automatically takes precedence over scene mode.
ENABLED Press EXECUTE to toggle scene mode from ENABLED to DISABLED.
DISABLED Press EXECUTE to toggle scene mode from DISABLED to ENABLED.
Any change in the conguration is automatically saved.