42. EEPROM View the type of EEPROM memory module plugged in.
All DE90-3000 Series retrot control systems come with a removable EEPROM
memory module located on the MADD-24 board mounted on the backplane.
The EEPROM memory module inserts into the PORT1 connector located on the
upper center of the board, and may be removed for safe storage.
The EEPROM type is programmed for parameter (P) or rmware (F) operation.
A parameter EEPROM is used to backup all of the current conguration settings.
A rmware EEPROM is used to update the current rmware version running on
the MADD-24 microcontroller to the rmware version saved on the EEPROM. The
EEPROM memory module supplied with all DE90-3000 Series retrot control systems
is a parameter type with all of the factory default conguration settings saved onto it
before shipping.
MADD24-P Indicates the EEPROM memory module is for a MADD-24 microcontroller.
MADD24-P Indicates the EEPROM type is programmed for parameter (P) operation.
XXXXXX Press EXECUTE to display the silicone serial number parameter.
DISABLED Press EXECUTE and menu feature is disabled for factory use only.
MADD24-F Indicates the EEPROM type is programmed for rmware (F) operation.
VER X.X Press EXECUTE to display the version (VER) of the rmware.
DISABLED Press EXECUTE and menu feature is disabled for factory use only.
NONE! Indicates the EEPROM memory module is not installed.
43. FW-LOAD Load new rmware into the MADD-24 via the EEPROM memory module.
If a rmware update is required, Johnson Systems Inc. may supply an EEPROM
memory module with the latest rmware version. The rmware EEPROM memory
module can be inserted into PORT1 on the MADD-24 board and the rmware can be
loaded into the microcontroller.
Press EXECUTE to enter the menu.
DISABLED This menu is disabled for inadvertent use. Proceed to enable.
ENABLED Press and hold MENU ( ) and MENU ( ) at the same time for 4-5 seconds.
MEMCHECK Automatically checks the EEPROM memory module for rmware type.
CRC-TEST Automatically does a CRC test on the rmware code in the EEPROM.
>>>>>>>> The CRC test in progress.
VER X.X Displays the rmware version on the EEPROM memory module.
UPDATE?? Press EXECUTE to proceed.
SURE ??? Press EXECUTE to proceed.
UPDATING Firmware update in progress.
WILL Firmware update in progress.
AUTO Firmware update in progress.
RESTART Firmware update in progress.
PLEASE Firmware update in progress.
WAIT.... When rmware update is complete the RUN LED ashes and system restarts.
NO MEM! Displayed if an EEPROM memory module is not detected.
WRONG Displayed if the wrong type (parameter) of EEPROM memory module detected.
MEM TYPE Displayed if the wrong type (parameter) of EEPROM memory module detected.
WRONG Displayed if the wrong product type of EEPROM memory module detected.
PRODUCT Displayed if the wrong product type of EEPROM memory module detected.
CRC ERR! Displayed if the CRC test fails and the EEPROM memory module is defective.
WARNING: Do not reset or turn the power off while the rmware is being updated.
Doing so will cause unrecoverable loss of rmware data that is being loaded into the
MADD-24 microcontroller.