User Manual CS-IPRO Wireless Hand-Held Programmer for CS-DMX Series Control Stations JOHNSON SYSTEMS INC. ET R O FI T Y CL EU REC SE ! R www.johnsonsystems.
R O FI Table of Contents T Y CL EU REC SE ! R ET Warranty...........................................................................................................2 User Manual Copies.........................................................................................2 Introduction.......................................................................................................3 E R Specifications........................................................................................
Introduction CS-IPRO is a wireless hand-held programmer used to communicate with and configure CS-DMX series control stations. The CS-IPRO features a removable EEPROM Memory Module used to save/backup the DMX channel patch configuration. The EEPROM Memory Module can be easily removed and stored in a safe place. Additional EEPROM Memory Modules are available if multiple backups are required. An EEPROM Memory Module may also be provided for firmware updates.
Battery Replacement 2 x AA Batteries Alkaline or Nickel Metal Hydride (NiMh) ONLY! Ensure batteries are installed as indicated inside the battery compartment. The combined voltage of the batteries must be greater than 1.9 VDC for the CS-IPRO to power on.
System Status - LCD Display The top line of the LCD display always shows “JSI IPRO” unless the configuration menu items are being accessed. The bottom line of the LCD display shows the current status. In normal run mode it will show “>REMOTE<”. If a low battery level (2.0V to 2.1V) is sensed, it will show “LOW BAT!” indicating the batteries need to be replaced. If a critical battery level (1.
Quick Programming Reference to System Configuration Menu Items 1. CHECK PATCH Check the DMX channel patch for each of the sliders. Checks the patch saved in the CS-IPRO memory only. 2. EDIT PATCH Edit the patch and assign DMX channel(s) to each of the sliders. Edits the patch saved in the CS-IPRO memory only. 3. CLEAR PATCH Clear the DMX channel patch for a selected slider or all sliders. Clears the patch saved in the CS-IPRO memory only. 4.
Detailed Programming of System Configuration Menu Items The sequence of the following system configuration menu items appear as the MENU DOWN ( switch is pressed. Pressing the MENU UP ( ) switch will sequence the system configuration menu items in the opposite order. Pressing and holding either of the MENU UP/DOWN ( ) switches will speed up the scroll rate, which can be helpful to speed up the configuration time. 1.
4. SET CS PATCH The DMX channel patch data in the programmer memory is sent and saved into a CS-DMX control station. The total transfer time to set the patch is approximately 110 milliseconds. Point the CS-IPRO infrared LED window directly at the CS-DMX infrared LED window, within 12" (30 cm). 5. SET CS SENDING OKAY COMM ERR CRC ERR! KEY ERR! INVALID Press EXECUTE to set the CS-DMX control station patch. Displayed briefly while data is being sent from the CS-IPRO.
8. EPPROM IPRO-X View the type of EEPROM memory module plugged into the CS-IPRO. The CS-IPRO comes with a removable EEPROM memory module. The EEPROM memory module inserts into the connector located on the front face of the CS-IPRO, and may be removed for safe storage. The EEPROM type is factory configured for parameter (P) or firmware (F) operation. A parameter EEPROM is used to backup the DMX channel patch configuration.
00000000 00000090 00000093 00000093 Press ESCAPE to move the cursor to the left or to exit the menu. Press MENU ( ) to adjust the selected digit (0 to 9). Repeat the previous 3 steps until the security key is complete. Press ESCAPE to exit the menu and save the security key. The menu will automatically timeout after 2 minutes of inactivity and save. 11. SET KEY SECURITY Set the security key for a CS-DMX control station.
15. FIRMWARE VER X.X VER X.X 16. SERIAL # XXXXXX XXXXXX 17. BATTERY X.X OKAY 3.0 OKAY 2.2 LOW 2.2 CRIT View the firmware version running on the CS-IPRO microcontroller. Indicates the firmware version running on the CS-IPRO microcontroller. View the CS-IPRO unique six-character silicone serial number. Indicates the CS-IPRO unique six-character silicone serial number. View the battery voltage level and status. The batteries should be replaced when a low (LOW) battery voltage level is detected.
CS-DMX Series Programmable Manual DMX Control Stations Model Description # Wires Back Box Minimum PCB Clearance CS-DMX-3-? 3 channel manual control w/master slider, on, preset, and off 2 x #18 AWG +DMX 2 gang 3.60"W x 2.75"H x 2.00"D 9.1cm x 7.0cm x 5.1cm CS-DMX-6-? 6 channel manual control w/master slider, on, preset, and off 2 x #18 AWG +DMX 3 gang 5.50"W x 2.75"H x 2.00"D 14.0cm x 7.0cm x 5.