Product Manual

©2015 Johnson Level & Tool 19
Y-direction self-check with the same method as X-direction
self-check, and mark point C and point D by turns.
7. If point C and point D are within 1/32" at 50’, the accuracy is
within tolerance. Otherwise reference section 12 of this
document.
Fine Calibration via Remote Control (sold separately)
1. Access calibration mode by simultaneously pressing the
“Power” and “Tilt” buttons on the keypad.
2. Press on/off button and Tilt mode button at the same time,
then release the on/off button and continue pressing the Tilt
mode button. After the Tilt LED and V-W-S LED start to flash,
release the Tilt mode button and the instrument will enter into
X-calibration status, the Tilt LED flashes and V-W-S LED light
is on and the instrument keeps rotating.
3. Release the “Tilt” button. Note that the rotating head of the
laser is not rotating and the laser is flashing. The unit is now in
calibration mode and all other operations will be performed
with the unit’s remote control (sold separately).
4. Use the remote control to access the calibration.
Pressing the “X/Y” button changes calibration control between
the X-axis and Y-axis. The X-axis is selected when the Tilt
button is flashing while all other buttons are solid. The
Y-axis is selected when the V-W-S light is solid. Once the
desired axis has been selected, the “UP Arrow” and “Down
Aarow” buttons are used to adjust the position of the
horizontal laser beam plane.