Brochure
Table Of Contents
- Valves and Actuators Catalog, PUBL-4087
- Product Categories
- Table of Contents
- Code Number Index
- Electric Damper Actuators
- M9102-AGA-2S, -3S and M9104-xGA-2S, -3S Series Electric Non-Spring-Return Actuators
- M9104-AGx-2N Electric Non-Spring-Return Actuators
- M9106-xGx-2 Series Electric Non-Spring-Return Actuators
- M9106-AGx-2N0x Series Electric Non-Spring-Return Actuators
- M9109-xGx-2 Series Electric Non-Spring-Return Actuators
- M9108, M9116, M9124, and M9132 Series Electric Non-Spring-Return Actuators
- M9203-xxx-2(Z) Series Electric Spring-Return Actuators
- M9208-xxx-x Series Electric Spring-Return Actuators
- M9220 Series Electric Spring-Return Actuators
- Direct Mount Actuator Accessories
- M9000-3xx Weather Shield Enclosures
- Pneumatic Damper Actuators
- D-3031 Pneumatic Piston Damper Actuator
- D-3062 Pneumatic Piston Damper Actuator
- D-3153, D-3244, D-3246 Pneumatic Actuators for VF Series Butterfly Valves
- D-4070 Pneumatic Piston Damper Actuator
- D-4073 Pneumatic Piston Damper Actuator
- DS-3062 High-Temperature Pneumatic Piston Damper Actuator
- DS-3153 High-Temperature Pneumatic Piston Damper Actuator
- D-9502 Pneumatic Damper Actuator Positioner
- Hardware for Pneumatic Damper Actuators
- Threaded Ball Valves and Actuators
- VG1000 Series Two-Way, Plated Brass Trim, NPT End Connections Ball Valves with Non-Spring-Return Electric Actuators
- VG1000 Series Three-Way, Plated Brass Trim, NPT End Connections Ball Valves with Non-Spring-Return Electric Actuators
- VG1000 Series Two-Way, Plated Brass Trim, NPT End Connections Ball Valves with Spring-Return Electric Actuators without Switches
- VG1000 Series Two-Way, Plated Brass Trim, NPT End Connections Ball Valves with Spring-Return Electric Actuators with Switches
- VG1000 Series Three-Way, Plated Brass Ball and Stem, NPT End Connections Ball Valve Assemblies with End Switches
- VG1000 Series Three-Way, Plated Brass Trim, NPT End Connections Ball Valves with Spring-Return Electric Actuators without Switches
- VG1000 Series Two-Way, Stainless Steel Trim, NPT End Connections Ball Valves with Non-Spring-Return Electric Actuators
- VG1000 Series Three-Way, Stainless Steel Trim, NPT End Connections Ball Valves with Non-Spring-Return Electric Actuators
- VG1000 Series Two-Way, Stainless Steel Trim, NPT End Connections Ball Valves with Spring-Return Electric Actuators without Switches
- VG1000 Series Two-Way, Stainless Steel Trim, NPT End Connections Ball Valves with Spring-Return Electric Actuators with Switches
- VG1000 Series Three-Way, Stainless Steel Trim, NPT End Connections Ball Valves with Spring-Return Electric Actuators without Switches
- VG1000 Series Three-Way, Stainless Steel Trim, NPT End Connections Ball Valves with Spring-Return Electric Actuators with Switches
- VG1000 Series Forged Brass Ball Valves for Assembly in the Field
- VG1000 Series Sweat End Connection Plated Brass Trim Ball Valves
- VG1000 Series Sweat End Connection Stainless Steel Trim Ball Valves
- VG1000 Series Press End Connection Stainless Steel Trim Ball Valves
- VA9104-xGA-2S, -3S Series Electric Non-Spring-Return Valve Actuators
- VA9203-xxx-xx Series Electric Spring-Return Actuators
- VA9208-xxx-xx Series Electric Spring-Return Actuators
- M9000-5xx Series Ball Valve Linkage Kits
- Threaded Globe Valves and Actuators
- VG7000 Series Brass Trim Globe Valves with VA-715x Series Electric Actuators
- VG7000 Series Brass Trim Globe Valves with VA-4233 Series Spring-Return Electric Actuators
- VG7000 Series Brass Trim Globe Valves with VA7800 Series Electric Actuators
- VG7000 Series Stainless Steel Trim Globe Valves with VA-715x Series Electric Actuators
- VG7000 Series Stainless Steel Trim Globe Valves with VA-4233 Series Spring-Return Electric Actuators
- VG7000 Series Stainless Steel Trim Globe Valves with VA7800 Series Electric Actuators
- VG7000 Series Brass Trim Globe Valves with V-3801 Compact Pneumatic Actuators
- VG7000 Series Brass Trim Globe Valves with V-3000 Pneumatic Actuators
- VG7000 Series Brass Trim Globe Valves with MP82 Series Pneumatic Actuators
- VG7000 Series Stainless Steel Trim Globe Valves with V-3000 Pneumatic Actuators
- VG7000 Series Stainless Steel Trim Globe Valves with MP82 Series Pneumatic Actuators
- VG7000 Series Stainless Steel Trim Globe Valves with MP84 Series Pneumatic Actuators
- VG7000 Series Bronze Globe Valves for Assembly in the Field
- VA-715x Series Electric Valve Actuator
- VA-4233 Series Electric Valve Actuators
- VA-720x Series Electric Valve Actuator
- VA7800 Series Electric Valve Actuators
- V-3801-8001 Pneumatic Valve Actuator
- V-3000-8012, V-3000-8003 Pneumatic Valve Actuators
- MP8000 Series Pneumatic Valve Actuators
- Repair Parts and Replacement Diaphragms for V-3000 Series Actuators
- VG7000 Series Bronze Globe Valves, Maintenance and Repair
- V-9502 Series Pneumatic Valve Actuator Positioners
- Repair Parts for Use with V-9502 Pneumatic Valve Actuator Positioner
- Zone and Fan Coil Valves
- J Series Electric Zone Valves — Two-Way Spring Open (Normally Open), On/Off Control
- J Series Electric Zone Valves — Two-Way Spring Closed (Normally Closed), On/Off Control
- J Series Electric Zone Valves — Two-Way Spring Open (Normally Open), Modulating Control
- J Series Electric Zone Valves — Three-Way Spring Return, On/Off Control
- J Series Electric Zone Valves for Assembly in the Field
- Flanged Globe or Ball Valves and Actuators
- VG1000 Series Flanged Ball Valves
- VG1000 Series Flanged Ball Valves for Assembly in the Field
- VG2000 Series Electric Cast Iron Flanged Globe Valves
- VG2000 Series Pneumatic Cast Iron Flanged Globe Valves
- VG2000 Series Cast Iron Flanged Globe Valves for Assembly in the Field
- VA-3100 Series Electric Valve Actuators
- VA-6100 Series Electric Valve Actuators
- MP8000 Series Pneumatic Valve Actuators
- V-9502 Series Pneumatic Valve Actuator Positioners
- M9000-5xx Series Ball Valve Linkage Kits
- M9000-53x Series Cast Iron Flanged Valve Linkage Kits
- VG2000 Series Cast Iron Flanged Globe Valves, Maintenance and Repair
- Butterfly Valves and Actuators
- M9000 Electrically Actuated, Standard-Pressure, Standard-Temperature, Two-Way Butterfly Valves (without Weather Shield)
- M9000 Electrically Actuated, Standard-Pressure, Standard-Temperature, Two-Way Butterfly Valves (with Weather Shield)
- Two-Way, Industrial-Grade, Non-Spring-Return, VA-90xx Series Electrically Actuated, Standard-Pressure, Standard-Temperature Butterfly Valve Assemblies
- Two-Way, Spring-Return, Low-Pressure D-3000 Series Pneumatically Actuated, Standard-Pressure, Standard-Temperature Butterfly Valve Assemblies
- Two-Way, Industrial-Grade, Spring-Return, V-919x Series High-Pressure Pneumatically Actuated, Standard-Pressure, Standard-Temperature Butterfly Valve Assemblies
- Two-Way, Industrial-Grade, Non-Spring-Return, V-909x Series High-Pressure Pneumatically Actuated, Standard-Pressure, Standard-Temperature Butterfly Valve Assemblies
- Two-Way, Industrial-Grade, Manually Operated, Standard-Pressure, Standard-Temperature Butterfly Valve Assemblies
- M9000 Series Electrically Actuated, Standard-Pressure, Standard-Temperature, Three-Way Butterfly Valves (without Weather Shield)
- M9000 Series Electrically Actuated, Standard-Pressure, Standard-Temperature, Three-Way Butterfly Valves (with Weather Shield)
- Three-Way, Industrial-Grade, Non-Spring-Return, VA-907x Series Electrically Actuated, Standard-Pressure, Standard-Temperature Butterfly Valve Assemblies
- Three-Way, Spring-Return, Low-Pressure D-3000 Series Pneumatically Actuated, Standard-Pressure, Standard-Temperature Butterfly Valve Assemblies
- Three-Way, Industrial-Grade, Spring-Return, V-919x Series High-Pressure Pneumatically Actuated, Standard-Pressure, Standard-Temperature Butterfly Valve Assemblies
- Three-Way, Industrial-Grade, Non-Spring-Return, V-909x Series High-Pressure Pneumatically Actuated, Standard-Pressure, Standard-Temperature Butterfly Valve Assemblies
- VF Series Two-Way, Industrial-Grade, Non-Spring-Return, VA-90xx Series Electrically Actuated, High-Pressure, High-Temperature Butterfly Valve Assemblies
- Two-Way, Industrial-Grade, Non-Spring-Return, V-909x Series High-Pressure Pneumatically Actuated, High-Pressure, High-Temperature Butterfly Valve Assemblies
- Two-Way, Industrial-Grade, Spring-Return, V-919x Series High-Pressure Pneumatically Actuated, High-Pressure, High-Temperature Butterfly Valve Assemblies
- Two-Way, Manually Operated, High-Pressure, High-Temperature Butterfly Valve Assemblies
- VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service
- V-9000 Series Rotary Motion Rack and Pinion Pneumatic Actuators for Butterfly Valves
- V-9000-500 Positioner
- Pressure-Independent Valves
- Other Valves and Actuators
- V-3766, V-3966, and V-4332 Brass Pneumatic Flare Valves, 1/2 in. Two-Way and Three-Way
- V-3802-1 Oval Top Actuator
- V-4334 Flare Valve
- V-4440 Series Water Valve 1/2 and 5/8 in. for Three- and Four-Pipe Systems
- VB-3766, VB-3966, VB-4332 Series Brass Flare Valve Bodies, 1/2 in. Two-Way and Three-Way
- V-3000 Series Pneumatic Actuator
- V-4000-1 Small Pneumatic Actuator for Small Control Valves
- V-9502 Series Pneumatic Valve Actuator Positioners
- Repair Parts for Use with V-9502 Pneumatic Valve Actuator Positioner
- Repair Parts for Use with Electric or Pneumatic VT Series Terminal Unit Valves 1/2 in., Two-Way and Three-Way
- Repair Parts for 1/2 in. Flare Valves for Use with V-3766, V-3966, V-4332, VB-3766, VB-3966, VB-4332, AV-8050, AV-8051, and AV-8052 (Flare Valve Assemblies)
- Repair Parts for Use with V-4334 5/8 in. Flare Valve
- Repair Parts for Use with V-4440 Water Valve 1/2 and 5/8 in. for Three- and Four-Pipe Systems
- Repair Parts for Cage Trim Valve for Use with V-3754 with Actuator and VB-3754 without Actuator (Including 1/2 in.)
- Repair Parts for Use with V-4324 with Actuator and VB-4324 without Actuator (Including 1/2 in.)
- Repair Parts for Use with V-3854 with Oval Top Actuator
- Repair Parts for Use with V-5254, V-5464, and V-5844 with V-5252 Size 4R Actuators
- Repair Parts for Use with V-3974 with Actuator and VB-3974 without Actuator (Including 1/2 in.)
- Repairs Parts for Cast Iron Flanged Globe Valves (2-1/2 through 6 in.) for Use with V-5252 and VB-3752
- Repairs Parts for Cast Iron Flanged Globe Valves (2-1/2 through 6 in.) for Use with V-5462 and VB-3970
- Repairs Parts for Cast Iron Flanged Globe Valves (2-1/2 through 6 in.) for Use with V-5842 and VB-4322
- Repair Parts for Use with V-7216 Two-Way Normally Open Steam or Water Valve
- Repair Parts for Use with V-7416 Two-Way Normally Closed Steam or Water Valve
- Repair Parts for Use with V-3752 Normally Open Valves 1/2 through 2 in.
- Repair Parts for Use with V-3755 Normally Open Valves, 1/2 through 2 in.
- Repair Parts for Use with VB-3752 Normally Open Steam and Water Valves
- Repair Parts For Use with V-3800 Normally Open Valves 1/2 and 3/4 in.
- Repair Parts for Use with V-5210 High-Pressure Normally Open Valve 2-1/2 through 4 in. Cast Iron 250 lb ANSI Raised Flanges
- Repair Parts for Use with V-5410 High-Pressure Normally Closed Valves 2-1/2 through 4 in. Cast Iron 250 lb ANSI Raised Flanges
- Valve Spring Kits Sorted by Valve Code Number
- Inner Valve Reconditioning Kits: 1/2 to 5/8 in.
- Inner Valve Reconditioning Kits: 3/4 to 2 in.
- Inner Valve Reconditioning Kits: 2-1/2 to 6 in.
- Valve Sizing and Cross-Reference
- Sizing Water Valves
- Valve Sizing Steam Applications
- Cross-Reference of VT Series Threaded (NPT) Valves to VG7000 Series Valves
- Cross-Reference of VT Series Union End Valves to VG7000 Series Valves
- Cross-Reference of Cage Trim Valves to VG7000 Series Valves
- Cross-Reference of V-7x16 Series Valves to VG7000 Series Valves
- Notes
- HVACR Product Offerings
- Sales Contact Information
The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2014 Johnson Controls, Inc.
www.johnsoncontrols.com
V–220
JM Series Two-Way Spring-Return
Modulating Zone Valve
J Series Electric Zone Valves — Two-Way Spring Open (Normally Open),
Modulating Control
Code No. LIT-1900191
Description
This electric zone valve with forged brass body
offers two-way spring open (normally open),
modulating control for hot or chilled water
applications.
Refer to the J Series Electric Zone Valves
Product Bulletin (LIT-977282) for important
product application information.
Selection Chart
Valve Size,
in.
Cv Closeoff,
psig
Actuator
Three-Wire
Floating
0 to 10 VDC
Proportional
JT13A000 JP13A000
Two-Way — Sweat Connections
JM2211 1/2 1 50 JM2211T23A000 JM2211P23A000
JM2212 1/2 2 50 JM2212T23A000 JM2212P23A000
JM2213 1/2 4 35 JM2213T23A000 JM2213P23A000
JM2312 3/4 2 50 JM2312T23A000 JM2312P23A000
JM2313 3/4 4 35 JM2313T23A000 JM2313P23A000
JM2317 3/4 7.5 35 JM2317T23A000 JM2317P23A000
JM2413 1 4 35 JM2413T23A000 JM2413P23A000
JM2417 1 8 35 JM2417T23A000 JM2417P23A000
JM2517 1-1/4 8 35 JM2517T23A000 JM2517P23A000
Two-Way — NPT Connections
JM2221 1/2 1 50 JM2221T23A000 JM2221P23A000
JM2222 1/2 2 50 JM2222T23A000 JM2222P23A000
JM2223 1/2 4 35 JM2223T23A000 JM2223P23A000
JM2322 3/4 2 50 JM2322T23A000 JM2322P23A000
JM2323 3/4 4 35 JM2323T23A000 JM2323P23A000
JM2327 3/4 7.5 35 JM2327T23A000 JM2327P23A000
JM2427 1 8 35 JM2427T23A000 JM2427P23A000
Features
• economical control of hot or chilled water
(up to 50% glycol) for fan coil, baseboard
radiator, and VAV reheat applications
• 0 to 10 VDC proportional and three-wire
floating control
• 32 to 200°F (0 to 93°C) fluid temperature
rating
• 32 to 125°F (0 to 52°C) ambient
temperature rating
• 300 psig static pressure rating
• 20 to 30 VAC 50/60 Hz
• forged brass body
Note: Actuators and valve bodies can be ordered separately using the
actuator and valve code numbers shown. JM Series Modulating
Three-Way Electric Zone Valves must be piped in a mixing
configuration only.
Repair Information
If the J Series Zone Valve fails to operate within its specifications,
replace the valve body, actuator, or entire assembly. For replacement
parts, contact the nearest Johnson Controls® representative.
Technical Specifications
J Series Electric Zone Valves —
Two-Way Spring Open (Normally Open), Modulating Control
Service
1
1. Refer to the VDI 2035 Guideline for recommended proper water treatment.
Hot Water, Chilled Water, and 50/50
Glycol Solutions for HVAC Systems
Fluid
Temperature
Limits
Water 32 to 200°F (0 to 93°C)
Steam Not Rated for Steam Service
Valve Body Pressure Rating 300 psig (2,067 kPa)
Leakage 0.01% of Maximum Flow per ANSI/FCI
70-2 Class IV
Ambient Operating Temperature
Limits
32 to 125°F (0 to 52°C)
Cycle Time Full Close to Full Open 150 Seconds
Control
Signal
T Type Actuator 24 VAC, 60 Hz, Three-Wire Floating
Control
P Type Actuator 0 to 10 VDC (1 to 9 VDC Actual) Factory
Setting,
0 to 5 VDC, 5 to 10 VDC Jumper
Selectable
Control
Action
P Type Actuator Factory Setting: Direct Acting
Valve Opens Port B as Signal Increases.
Jumper Selectable
Power Requirements 1.6 VA
Electrical Connection Terminal Block
Materials Body Brass
Stem Brass (Hard Chrome Plated)
Base Plate and
Bearing Plate
Stainless Steel
Actuator Housing High-Temperature Plastic
Valve Plug High-Temperature Thermoplastic Rubber
Stem Seals Viton™ O-Rings
Zone and Fan Coil Valves
Zone and Fan Coil ValvesZone and Fan Coil Valves