Brochure

Table Of Contents
The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2014 Johnson Controls, Inc.
www.johnsoncontrols.com
V–133
VG1000 Series Forged Brass Ball Valves for Assembly in the Field (Continued)
Threaded Ball Valves and Actuators
1 (DN25) VG1241Cx
VG1245Cx
VG1841Cx
VG1845Cx
VG1275Ax
VG1875Ax
VG1295Ax
VG1895Ax
VA9104
2
None Required (Fluid Temperatures < 212°F [100°C])
M9000-561 (Thermal Barrier for Fluid Temperatures
> 212°F [100°C])
M9000-341
M9104
2
M9000-551 (Fluid Temperatures < 212°F [100°C])
M9000-551 and Thermal Barrier M9000-561 (Fluid
Temperatures > 212°F [100°C])
M9000-341
M9106
2
M9000-520 M9000-341
M9108 M9000-516 M9000-330
VA9203 None Required (Fluid Temperatures < 212°F [100°C])
M9000-561 (Thermal Barrier for Fluid Temperatures
> 212°F [100°C])
M9000-341
M9203 M9000-551 (Fluid Temperatures < 212°F [100°C])
M9000-551 and Thermal Barrier M9000-561 (Fluid
Temperatures > 212°F [100°C])
M9000-341
1-1/4 (DN32) VG1241Dx
VG1245Dx
VG1841Dx
VG1845Dx
M9106
2
M9000-520
M9108 M9000-516 M9000-330
VA9208 None Required (Fluid Temperatures < 212°F [100°C])
M9000-561 (Thermal Barrier for Fluid Temperatures
> 212°F [100°C])
M9000-341
M9208 M9000-561 (Fluid Temperatures < 212°F [100°C])
M9000-560 and Thermal Barrier M9000-561 (Fluid
Temperatures > 212°F [100°])
M9000-341
1-1/2 (DN40) VG1241Ex
VG1245Ex
VG1841Ex
VG1845Ex
M9106
2
M9000-520
M9108 M9000-516 M9000-330
VA9208 None Required (Fluid Temperatures < 212°F [100°C])
M9000-561 (Thermal Barrier for Fluid Temperatures
> 212°F [100°C])
M9000-341
M9208 M9000-561 (Fluid Temperatures < 212°F [100°C])
M9000-560 and Thermal Barrier M9000-561 (Fluid
Temperatures > 212°F [100°])
M9000-341
2 (DN50) VG1241Fx
VG1245Fx
VG1841Fx
VG1845Fx
M9109
2
M9000-520
M9116 M9000-516 M9000-330
VA9208 None Required (Fluid Temperatures < 212°F [100°C])
M9000-561 (Thermal Barrier for Fluid Temperatures
> 212°F [100°C])
M9000-341
M9208 M9000-561 (Fluid Temperatures < 212°F [100°C])
M9000-560 and Thermal Barrier M9000-561 (Fluid
Temperatures > 212°F [100°])
M9000-341
1. VA9104, M9104, M9106, M9109, and M9100 Series Actuators are non-spring-return, and VA9203 and VA9208 Series Actuators are spring-return. Note:
VA9104, M9104, VA9203, and VA9208 have a maximum fluid temperature limit of 212°F (100°C) unless used with the M9000-561 Thermal Barrier.
2. To avoid excessive wear or drive time on the motor for VA9104, M9104, M9106, and M9109 AGx models, use a controller and/or software that provides a
timeout function to remove the signal at the end of rotation (stall). The IGx and GGx models have an automatic shutoff to avoid excessive wear or drive time on
the motor.
Valid Ball Valve, Electric Actuator, Linkage Kit, and Weather Shield Combinations (for Assembly in the Field) (Part 2 of 2)
Valve Size,
in. (mm)
Valve Code Numbers Actuator Base
Number
1
Linkage Kit Code Number Weather Shield
NPT End
Connection
Sweat End
Connection
Press End
Connection
Threaded Ball Valves and
Actuators
Threaded Ball Valves and
Actuators
Threaded Ball Valves and
Actuators
Threaded Ball Valves and
Actuators