VG1000 Series Forged Brass Ball Valves for Assembly in the Field
300 Series Stainless Steel Ball and Stem
Assembly — tolerates high-temperature
water or 15 psi saturated steam with fluid
temperatures of -22 to 284F (-30 to
140C) or where a higher degree of
corrosion protection is desired.
Ethylene Propylene Diene Monomer
(EPDM) Double O-ring Steam Seal —
provides a leak-free seal; the packing has
been tested and is leak-free after 200,000
cycles in iron-oxide contaminated water.
Graphite-Reinforced
Polytetrafluoroethylene (PTFE) Seats —
include 15% graphite-reinforced ball seals,
providing better wear resistance.
200 psi Closeoff Pressure Rating —
provides tight shutoff.
500:1 Rangeability — provides accurate
control under all load conditions.
Chrome-Plated Brass Ball and Stem
Assembly Standard — handles both chilled
and hot water applications with a fluid
temperature range of 23 to 203°F (-5 to
95°C).
Blowout-Proof Stem — protects the user
from the risk of injury.
Description
VG1000 Series Ball Valves are designed to
regulate the flow of hot or chilled water and, for
some models, low-pressure steam in
response to the demand of a controller in
HVAC systems. Available in sizes 1/2 through
2 in. (DN15 through DN50), this family of
two- and three-way forged brass valves is
factory or field mounted to Johnson Controls®
VA9104, M9106, M9109, and M9100 Series
Non-Spring-Return and VA9203 and
VA9208 Series Spring-Return Electric
Actuators for on/off, floating, or proportional
control.
Refer to the VG1000 Series Forged Brass Ball
Valves Product Bulletin (LIT-977132) for
important product application information.
Features
National Pipe Thread (NPT), Sweat, and
Press End Connections — provide the right
valve for a broad range of applications,
reduce installation time while reducing the
need for adapters, and increase system
reliability.
Selection Charts
Valid Ball Valve, Electric Actuator, Linkage Kit, and Weather Shield Combinations (for Assembly in the Field) (Part 1 of 2)
Valve Size,
in. (mm)
Valve Code Numbers Actuator Base
Number
1
Linkage Kit Code Number Weather Shield
NPT End
Connection
Sweat End
Connection
Press End
Connection
1/2 (DN15) VG1241Ax
VG1245Ax
VG1841Ax
VG1845Ax
VG1275Ax VG1895Ax VA9104
2
None Required (Fluid Temperatures < 212°F [100°C])
M9000-561 (Thermal Barrier for Fluid Temperatures
> 212°F [100°C])
M9000-341
M9104
2
M9000-551 (Fluid Temperatures < 212°F [100°C])
M9000-551 and Thermal Barrier M9000-561 (Fluid
Temperatures > 212°F [100°C])
M9000-341
M9106
2
M9000-520 M9000-341
M9108 M9000-516 M9000-330
VA9203 None Required (Fluid Temperatures < 212°F [100°C])
M9000-561 (Thermal Barrier for Fluid Temperatures
> 212°F [100°C])
M9000-341
M9203 M9000-551 (Fluid Temperatures < 212°F [100°C])
M9000-551 and Thermal Barrier M9000-561 (Fluid
Temperatures > 212°F [100°C])
M9000-341
3/4 (DN20) VG1241Bx
VG1245Bx
VG1841Bx
VG1845Bx
VG1275Ax
VG1875Ax
VG1295Ax
VG1895Ax
VA9104
2
None Required (Fluid Temperatures < 212°F [100°C])
M9000-561 (Thermal Barrier for Fluid Temperatures
> 212°F [100°C])
M9000-341
M9104
2
M9000-551 (Fluid Temperatures < 212°F [100°C])
M9000-551 and Thermal Barrier M9000-561 (Fluid
Temperatures > 212°F [100°C])
M9000-341
M9106
2
M9000-520 M9000-341
M9108 M9000-516 M9000-330
VA9203 None Required (Fluid Temperatures < 212°F [100°C])
M9000-561 (Thermal Barrier for Fluid Temperatures
> 212°F [100°C])
M9000-341
M9203 M9000-551 (Fluid Temperatures < 212°F [100°C])
M9000-551 and Thermal Barrier M9000-561 (Fluid
Temperatures > 212°F [100°C])
M9000-341
VG1000 Series Ball Valves
Code No. LIT-1924515
Threaded Ball Valves and Actuators
Threaded Ball Valves and
Actuators
Threaded Ball Valves and
Actuators