Install Instructions
Table Of Contents
- Applications
- North American emissions compliance
- United States
- Canada
- Installation
- Parts included
- Location considerations
- Installing the thermostat controller
- Wiring
- Setup and adjustments
- Overview
- Customizing the home screen
- Touchscreen icons
- User lockout
- Using the USB port
- Loading the firmware
- Backing up the settings
- Restoring the settings
- Choosing the Communication mode (TEC3612 and TEC3613 Models)
- Configuring the network settings for wireless models
- Configuring the thermostat controller
- Installer configuration menu
- Screen reset
- Selecting the unit type
- By default, the thermostat controller is configured for four-pipe fan coil mode. To change to a two-pipe or Pressure-Dependent VAV mode:
- Selecting the heating and cooling device type
- Configuring the supply fan - fan coil only
- Setting the Control mode
- Setting the Fan mode - fan coil only
- Configuring the zone space or equipment size - units configured with floating actuators, multi- speed fans, and variable-speed fans only
- Changeover
- Dehumidification control - fan coil only
- Temperature setpoints
- Configuring occupancy
- Selecting schedule source
- Scheduling (for networked models)
- Setting the local schedule
- Overriding the Occupancy mode
- Enabling optimal start
- Enabling the motion sensor (TEC3x12, TEC3x13 Models)
- PID/PRAC+ automatic control tuning
- Configurable binary inputs
- Aux control
- Commissioning mode
- Configurable analog inputs (AIs)
- Configuring the AIs
- Networked sensors
- Availability of AIs
- Priority for configurable AIs
- Priority for overall sensors data sources
- Available fault diagnostics
- Menus and submenus
- Troubleshooting
- Repair information
- Technical specifications
- TEC3000 Series Networked and Wireless On/Off or Floating Fan Coil and Individual Zone Thermostat Controllers with Dehumidification Capability (Part 1 of 3)
TEC3000 Series Networked and Wireless On/Off or Floating Fan Coil and Individual Zone Thermostat Controllers
with Dehumidification Capability Installation Guide
48
Thermistor
(2.2k ohm)
Adjustable 8 in. (203 mm) TE-6341A-1
Duct 8 in. (203 mm) TE-6341P-1
Flange 4 in. (102 mm) TE-634GV-2
8 in. (203 mm) TE-6341V-2
Outside air 3 in. (76 mm) TE-6343P-1
Wall
2
N/A TE-6344P-1
Well 8 in. (203 mm) TE-6342M-1
6 in. (152 mm) TE-634AM-2
Thermistor
(10k ohm)
Type II
Adjustable 8 in. (203 mm) TE-6361A-1
Duct 4 in. (102 mm) TE-636GM-1
8 in. (203 mm) TE-6361M-1
TE-6361P-1
18 in. (457 mm) TE-636JM-1
Flange 4 in. (102 mm) TE-636GV-2
8 in. (203 mm) TE-6361V-2
Flush N/A TE-6360F-0
TE-6360F-1
Outside air 3 in. (76 mm) TE-6363P-1
Strap-mount 3 in. (76 mm) TE-636S-1
Well 6 in. (152 mm) TE-636AM-2
8 in. (203 mm) TE-6362M-1
1. Two TE-6001-8 Element Holders come with the platinum-equivalent averaging sensors. Order separately to use with a
nickel averaging sensor.
2. Order the TE-1800-9600 Mounting Hardware separately to mount the wall unit to a wallbox.
Table 14: TE-6300 Series Temperature Sensors (order separately) (for wireless TEC Models) (Part 2 of 2)
Sensor type Mounting style Probe length Product code number