Install Instructions
Table Of Contents
- Applications
 - North American emissions compliance
 - United States
 - Canada
 - Installation
 - Parts included
 - Location considerations
 - Installing the thermostat controller
 - Wiring
 - Setup and adjustments
 - Overview
 - Customizing the home screen
 - Touchscreen icons
 - User lockout
 - Using the USB port
 - Loading the firmware
 - Backing up the settings
 - Restoring the settings
 - Choosing the Communication mode (TEC3612 and TEC3613 Models)
 - Configuring the network settings for wireless models
 - Configuring the thermostat controller
 - Installer configuration menu
 - Screen reset
 - Selecting the unit type
 - By default, the thermostat controller is configured for four-pipe fan coil mode. To change to a two-pipe or Pressure-Dependent VAV mode:
 - Selecting the heating and cooling device type
 - Configuring the supply fan - fan coil only
 - Setting the Control mode
 - Setting the Fan mode - fan coil only
 - Configuring the zone space or equipment size - units configured with floating actuators, multi- speed fans, and variable-speed fans only
 - Changeover
 - Dehumidification control - fan coil only
 - Temperature setpoints
 - Configuring occupancy
 - Selecting schedule source
 - Scheduling (for networked models)
 - Setting the local schedule
 - Overriding the Occupancy mode
 - Enabling optimal start
 - Enabling the motion sensor (TEC3x12, TEC3x13 Models)
 - PID/PRAC+ automatic control tuning
 - Configurable binary inputs
 - Aux control
 - Commissioning mode
 - Configurable analog inputs (AIs)
 - Configuring the AIs
 - Networked sensors
 - Availability of AIs
 - Priority for configurable AIs
 - Priority for overall sensors data sources
 - Available fault diagnostics
 - Menus and submenus
 - Troubleshooting
 - Repair information
 - Technical specifications
 - TEC3000 Series Networked and Wireless On/Off or Floating Fan Coil and Individual Zone Thermostat Controllers with Dehumidification Capability (Part 1 of 3)
 
TEC3000 Series Networked and Wireless On/Off or Floating Fan Coil and Individual Zone Thermostat Controllers 
with Dehumidification Capability Installation Guide
48
Thermistor
(2.2k ohm)
Adjustable 8 in. (203 mm) TE-6341A-1
Duct 8 in. (203 mm) TE-6341P-1
Flange 4 in. (102 mm) TE-634GV-2
8 in. (203 mm) TE-6341V-2
Outside air 3 in. (76 mm) TE-6343P-1
Wall
2
N/A TE-6344P-1
Well 8 in. (203 mm) TE-6342M-1
6 in. (152 mm) TE-634AM-2
Thermistor
(10k ohm)
Type II
Adjustable 8 in. (203 mm) TE-6361A-1
Duct 4 in. (102 mm) TE-636GM-1
8 in. (203 mm) TE-6361M-1
TE-6361P-1
18 in. (457 mm) TE-636JM-1
Flange 4 in. (102 mm) TE-636GV-2
8 in. (203 mm) TE-6361V-2
Flush N/A TE-6360F-0
TE-6360F-1
Outside air 3 in. (76 mm) TE-6363P-1
Strap-mount 3 in. (76 mm) TE-636S-1
Well 6 in. (152 mm) TE-636AM-2
8 in. (203 mm) TE-6362M-1
1. Two TE-6001-8 Element Holders come with the platinum-equivalent averaging sensors. Order separately to use with a 
nickel averaging sensor.
2. Order the TE-1800-9600 Mounting Hardware separately to mount the wall unit to a wallbox.
Table 14: TE-6300 Series Temperature Sensors (order separately) (for wireless TEC Models) (Part 2 of 2)
Sensor type Mounting style Probe length Product code number










