TE-6300 Series Temperature Sensors (Continued)
Materials Probes Nickel Averaging: 0.094 in. (2.4 mm) Outside Diameter (O.D.) copper tubing
Nickel Averaging Adaptor: 0.25 in. (6.35 mm) O.D. Brass
Platinum Averaging Probe: 0.19 in. (4.8 mm) Aluminum tubing
All others (except Averaging): 0.25 in. (6.35 mm) O.D. Stainless Steel
TE-63xxA Mounting Adapter Plate and Gland: Thermoplastic
TE-63xxF Flush Mount: Stainless Steel
TE-63xxM Enclosure: Corrosion-Protected Steel
Well Sensor Holder: 0.875 in. (22.2 mm) Hex Brass
TE-63xxP Conduit box and Shield: Rigid Thermoplastic
Mounting Plate: Aluminum
Sensor Holder: Rigid Thermoplastic
Wall Mount Base Plate: Corrosion-Protected Steel
Wall Mount Cover: Rigid Thermoplastic (White)
Wall Mount Face Plate: Brushed Aluminum
TE-63xxV Mounting Flange: Stainless Steel
Operating
Conditions
TE-63xxA -50 to 140°F (-46 to 60°C)
TE-63xxF 32 to 104°F (0 to 40°C)
TE-63xxM -50 to 220°F (-46 to 104°C)
TE-63xxP Enclosure: -50 to 122°F (-46 to 50°C)
Sensor Probe: -50 to 220°F (-46 to 104°C)
TE-63xS Sensor Probe: -50 to 220°F (-46 to 104°C)
Wire Harness: -50 to 122°F (-46 to 50°C)
TE-63xxV
Shipping Weight TE-63xxA 0.2 lb (0.09 kg)
TE-63xxF 0.25 lb (113.4 kg)
TE-63xxM Duct Averaging: 0.9 lb (0.41 kg)
Duct Mount: 0.4 lb (0.18 kg)
Well Insertion: 0.5 lb (0.23 kg)
TE-63xxP Duct Averaging: 0.5 lb (0.23 kg)
Duct Mount: 0.4 lb (0.18 kg)
Outdoor Air: 0.5 lb (0.23 kg)
Wall Mount: 0.2 lb (0.09 kg)
Well Insertion: 0.35 lb (0.16 kg)
TE-63xS Strap-Mount: 0.2 lb (0.09 kg)
TE-63xxV Duct Averaging: 0.7 lb (0.32 kg)
Duct Mount: 0.2 lb (0.09 kg)
Dimensions
(H x W x D)
TE-63xxA 2.17 in. (55 mm) diameter plus 4 or 8 in. (102 or 203 m) element
TE-63xxF Flush Mount: 4-1/2 x 2-3/4 in. (114 x 70 mm)
TE-63xxM Duct Averaging: 1.87 x 1.87 x 1.80 in. (47.5 x 47.5 x 45.8 mm) plus 8 or 17 ft (2.4 or 5.2 m)
element
Duct Mount: 1.87 x 1.87 x 1.80 in. (47.5 x 47.5 x 45.8 mm) plus 4, 8, or 18 in.
(102, 203, or 457 mm) element
Well Insertion: 1.87 x 1.87 x 1.80 in. (47.5 x 47.5 x 45.8 mm) plus 6 or 8 in. (152 or 203 mm)
element
TE-63xxP Duct Averaging: 5.97 x 1.38 x 2.75 in. (152 x 35 x 70 mm) plus 8, 10, 17, or 20 ft
(2.4, 3.0, 5.2, or 6.1 m) element
Duct Mount: 5.97 x 1.38 x 2.75 in. (152 x 35 x 70 mm) plus 6 or 8 in. (152 or 203 mm) probe
Outdoor Air: 5.97 x 3.47 x 4.46 in. (152 x 88 x 113 mm)
Wall Mount: 2.09 x 3.12 x 1.80 in. (53 x 79 x 46 mm)
Well Insertion: 5.97 x 1.38 x 2.75 in. (152 x 35 x 70 mm) plus 6 or 8 in. (152 or 203 mm) probe
TE-63xS Strap-Mount: 0.25 in. (6.35 mm) diameter x 3.00 in. (76 mm.) long
TE-63xxV Duct Averaging: 2.25 x 1.50 in. (57 x 38 mm) plus 8 or 17 ft (2.4 or 5.2 m) element
Duct Mount: 2.25 x 1.50 in. (57 x 38 mm) plus 4 or 8 in. (102 or 203 m) element