Inc. Air Conditioner User Manual

505430-BTG-A-0309
74 Johnson Controls Unitary Products
Electrical Data For Indoor Models
Electrical Data - Indoor Units
Motor HP Power Supply
Supply
Blower
Motor
Electric Heat Option
MCA
1
(Amps)
Max Fuse
2
/
Breaker
3
Size
(Amps)
FLA Model KW Stages Amps
NH-07C00B
1.5
208-3-60 5.0
None --- --- --- 11.3 15
10 KW 7.5 1 20.8 32.1 35
16 KW 12 2 33.4 44.6 45
26 KW 19.5 2 54.2 65.5 70
36 KW 27 2 75.1 86.3 90
230-3-60 5.0
None --- --- --- 11.3 15
10 KW 10 1 24.1 35.3 40
16 KW 16 2 38.5 49.7 50
26 KW 26 2 62.5 73.8 80
36 KW 36 2 86.6 97.9 100
460-3-60 2.5
None --- --- --- 5.6 15
10 KW 10 1 12.0 17.7 20
16 KW 16 2 19.2 24.9 25
26 KW 26 2 31.3 36.9 40
36 KW 36 2 43.3 48.9 50
575-3-60 2.0
None --- --- --- 4.5 15
10 KW 10 1 9.6 14.1 15
16 KW 16 2 15.4 19.9 20
26 KW 26 2 25.0 29.5 30
36 KW 36 2 34.6 39.1 40
NH-07C00C, NH/NJ-10C00C,
2.0
208-3-60 6.3
None --- --- --- 14.2 15
10 KW 7.5 1 20.8 35.0 40
16 KW 12 2 33.4 47.5 50
26 KW 19.5 2 54.2 68.4 70
36 KW 27 2 75.1 89.2 90
230-3-60 6.3
None --- --- --- 14.2 15
10 KW 10 1 24.1 38.2 40
16 KW 16 2 38.5 52.7 60
26 KW 26 2 62.5 76.7 80
36 KW 36 2 86.6 100.8 110
460-3-60 3.2
None --- --- --- 7.2 15
10 KW 10 1 12.0 19.2 20
16 KW 16 2 19.2 26.4 30
26 KW 26 2 31.3 38.5 40
36 KW 36 2 43.3 50.5 60
575-3-60 2.4
None --- --- --- 5.4 15
10 KW 10 1 9.6 15.0 20
16 KW 16 2 15.4 20.8 25
26 KW 26 2 25.0 30.4 35
36 KW 36 2 34.6 40.0 45