User Guide
Table Of Contents
P
—P100 Series Encapsulated Pressure Controls Product/Technical Bulletin
5
O
rdering Information
Standard P100 Control Models
Standard model P100 encapsulated pressure controls
are available in single and quantity orders through
Johnson Controls authorized distributors. Standard
P100 control model features are listed in Table 1. Also,
see Figure 1 for examples of standard models.
Non-Standard P100 Control Models
Non-standard P100 controls, built to customer
specifications, are also available.
Most non-standard
models require a minimum order of at least 100
controls. Some models require a 250 piece
minimum.
Refer to Table 2, Figure 5, and the following list for
available P100 control options. Contact Refrigeration
Application Engineering at (414) 524-5535 to place
quantity orders for non-standard P100 control models.
Control Options for Quantity Orders
Pressure Setpoints
Setpoints between 10 in. Hg and 750 psig, and
differentials up to 200 psi are available. Determine the
required high setpoint for manual reset controls, and
the high and low setpoints for automatic reset controls.
Thermal Isolation Fitting (TIF) Options
•
2 in. straight, 1/4 in. diameter TIF
•
2 in. nibbed, 1/4 in. diameter TIF
•
2 in. straight, 1/4 in. diameter TIF with bulge stop
Threaded Brass Female Fitting Options
•
1/4 in. SAE brass female flare fitting with internal
Schrader valve depressor
•
1-1/2 in. straight 1/4 in. diameter copper tube with
1/4 in. SAE female flare nut
•
1/8 in. -27 NPT
Threaded Brass Male Fitting Options
•
1/4 in. -18 NPT
•
1/8 in. -27 NPT
•
1/4 in. SAE flare
Copper Capillary Tube Options
(Available in 12, 24, and 36 in.)
•
Copper capillary tube (.093 in. outside diameter)
•
Copper capillary tube (.093 in. outside diameter)
with 1/4 in. bulbed termination
•
Copper capillary tube (.093 in. outside diameter)
with 1/4 in. bulbed termination with bulge stop
Control Switch Action Options
•
Open-high, automatic reset
•
Open-low, automatic reset
•
Open-high, manual reset
Electrical Contact Options
(See
Electrical Ratings
.)
•
SPST Standard duty
•
SPST Heavy duty
•
SPDT Heavy duty
Electrical Termination Options
•
Wire leads with 1/2 in. stripped ends
•
Wire leads with 1/4 in. male or female
quick-connect terminals
•
1/4 in. male quick-connect spade terminals on
control body (automatic reset models only)
Wire leads are available in various lengths.
Control Enclosure Options
•
Open (no enclosure or conduit clamp)
•
Conduit clamp for 3/8 in. flexible metal conduit
•
Conduit box with hole for 1/2 in. conduit connector
Figure 5: Examples of Non-Standard P100
Pressure Control