P100 Series
Encapsulated Pressure Switches
Code No. LIT-1927275
Issued February 1, 2009
Description
P100 Series switches are encapsulated,
nonadjustable, SPST, direct-mount switches
for use with noncorrosive refrigerants. The
switches are available with automatic reset in
both open low and open high configurations
and manual reset with open high action.
Features
• compact size and light weight allow for
direct mounting
• trip-free manual reset (manual reset
models)...contacts cannot be overridden
by continued depression of the reset
button
• use with all non-corrosive refrigerants
• encapsulated switch, dust tight
• 1/4 in. female flare fitting with built-in
Schrader type depressor is standard
• electrical connections are made to 48 in.
leads
Applications
• low limit, high limit, and fan cycling control
in commercial refrigeration
• ice machines
• food service equipment
Selection Chart
Code
Number
Switch
Action
Application Setting – psig (kPa) Replaces:
Opens Closes Gemline Ranco Robertshaw Saginomiya
P100AP-201C
Open On
Pressure
Drop
Low Cutout
10 (69) 32 (221) – MPL-7011 3100-050 –
P100AP-2C 35 (241) 60 (414) – MPF-7004 3100-004 –
P100AP-9C
1
1. 18 in. wire leads
25 (172) 80 (52) – – – –
P100AP-3C
Fan Cycling
150 (1034) 225 (1551) – MPF-7008 – ABC-AA01
P100AP-4C 170 (1172) 250 (1724) – – – –
P100AP-332C
2
2. Compatible with R410A refrigerant
300 (2068) 400 (2758) – – – –
P100AC-1C
3
3. Includes conduit clamp (shown above)
Low Cutout
5 (34) 20 (138) – MPL-7001 – –
P100AC-2C
3
15 (103) 30 (207) – MPL-7002 – –
P100CP-1C
Open On
Pressure
Rise
High Cutout
400 (2758) 300 (2068) PC151 MPH-7107 3100-151 –
P100CP-2C 425 (2930) 325 (2241) PC100 MPH-7108 3100-100 –
P100CP-85C
2
4
4. 1/4 in. male spade terminals
665 (4585) 565 (3896) – – – –
P100CC-9C
3
275 (1896) 175 (1207) – – 3100-112 –
P100DA-1C
High Limit
410 (2827)
Lockout
Manual Reset
PC103 – 3100-103 –
P100DA-2C 475 (3275) – – 3100-106 –
P100DA-35C 350 (2413) – – – –
P100DA-81C
2
630 (4344) – – – –
P100DA-86C
2
575(3964) – – – –
P100DC-3C
5
5. In conduit box
375 (2586) – – – –
Technical Specifications
Electrical Ratings
Ratings 120
VAC
240
VAC
AC Full Load A (FLA) 5.8 2.9
AC Locked Rotor A (LRA) 34.8 15.0
Pilot Duty – 375 VA at 120/240/277 VAC;
2 A at 28 VAC/VDC
P100