Johnson Controls Unitary Products Steam Humidifier Model 8000 Residential Steam Humidifier Owner’s Manual Includes Safety & Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS CAUTION Safety Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Principles of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INTRODUCTION Figure 1 – Fill and Drain System and Canister Thank you for your recent steam humidifier purchase. We appreciate your business and are pleased to add your name to our growing list of customers. You have invested in the highest quality equipment available. Your humidifier will require periodic maintenance to assure continued consistent performance. See page 10. Steam Outlet Fill Cup Overflow High Water Level Sensor Please take a few minutes and read this booklet.
INSTALLATION OPTIONS AND EFFECT OF WATER CHARACTERISTICS Your Steam Humidifier can be installed to operate using 120 Volts, 208 Volts or 240 Volts. The higher the voltage, the higher the potential output: Voltage Rated Output 120 Volts 4 lbs./hour (11.5 gallons/day maximum) 208 Volts 7 lbs./hour (20.5 gallons/day maximum) 240 Volts 8 lbs./hour (23.
TABLE 1 – Display Panel (continued) Indicator Light Function Solid Green Normal Operation. Humidistat is calling for steam and humidifier is operating. Solid Yellow Humidifier is operating but is not delivering steam at rated capacity. Occurs if humidifier has operated for 168 hours at less than rated capacity due to low water conductivity. Light will turn green once water conductivity increases and humidifier is delivering rated capacity. Flashing Green Humidifier is preparing to drain.
Check the Humidifier Operation Turn the control knob to the maximum RH setting. Make sure that the water saddle valve is open and that the humidifier is on. The indoor unit blower must be running for the humidifier to function. Once humidifier operation is verified, reduce the Humidifier Control setting to the recommended inside humidity, depending on the outside temperature. If using the automatic humidifier control model number S1-HUSTATAUTO56, Do not leave in test mode as humidifier will not operate.
limited warranty UPG warrants this product to be free from defects in factory workmanship and material under normal use and service and will, at its option, repair or replace any parts that prove to have such defects according to the terms outlined on this warranty. This warranty covers only the equipment described by the Product Model Number and Serial Number listed on the Warranty Registration Card. For your benefit and protection, return the Warranty Registration Card to UPG promptly after installation.