Product Overview

System 450™ Series Modular Controls Product Bulletin 3
System 450 Applications
You can create a wide variety of custom,
application-specific control systems with System 450
modules. The following are some common control
application examples:
temperature control
pressure control
humidity control
multipurpose control
reset and setback control
high input-signal selection
differential control
Temperature Control
Temperature control application examples include:
heating and/or cooling control
heating and cooling control with deadband
boiler temperature stage control
boiler circulating pump control
chilled water temperature stage control
discharge air temperature control
modulating damper or valve control
Pressure Control
Pressure control application examples include:
refrigeration compressor capacity control
staged SPDT condenser fan control
two-speed fan motor control
floating pressure control of an actuator
constant static pressure or air velocity control
relief damper building pressurization control
relief fan building pressurization control
Electronically Commutated (EC) motor control
(C450CPW-100 model)
Humidity Control
Humidity control examples include:
humidification/dehumidification control
staged SPDT humidity control
Multipurpose Control
Multipurpose application examples include:
temperature and pressure based refrigeration rack
control
temperature and humidity control for a wine cellar
or greenhouse
temperature, static pressure, and humidity for a
clean room application
Reset and Setback Control
Reset and setback control applications include:
temperature control for single stage or
multi-stage (up to ten stages) boilers with or
without load balancing (equal runtime hours)
humidity reset and temperature control for
natatorium/swimming pool zones
High Input Signal Selection
Beginning with firmware Version 2.00, standard System
450 control modules include the High Input-Signal
Selection control capability.
The High Input-Signal Selection feature enables a
System 450 control system to monitor a condition
(temperature, pressure, or humidity) with two or three
sensors (of the same type) and control relay and/or
analog outputs based on the highest condition value
sensed by the two or three referenced sensors.
High Input Signal Selection examples include:
fan-staging control on multi-circuit condensers
fan speed control on multi-circuit condensers
Differential Control
Beginning with Version 2.00 firmware, standard System
450 control modules also include Differential Control
capability.
Differential control is used to monitor and maintain a
given difference in a condition (temperature, pressure,
or humidity) between two sensor points within a
system, process, or space.
The Differential Control feature enables a System 450
control system to monitor the temperature, pressure, or
humidity differential between two sensors of the same
type (Sn-1 and Sn-2) and control relay and/or analog
outputs based on the sensed differential value relative
to user-selected differential values.
Differential Control application examples include:
solar heating systems
pump pressure-drop monitoring and control
fluid filter pressure-drop monitoring