Brochure
Table Of Contents
- Refrigeration Products Catalog, PUBL-5510
- Product Catagories
- Table of Contents
- Code Number Index
- Single-Stage Electromechanical Temperature Controls
- A11 Series Low Temperature Cutout Controls
- A19 Series Remote Bulb Control
- A19 Series High Range Temperature Control
- A19 Series Thermostat for Crop Drying
- A19 Series Hot Water Temperature Control (Well Immersion)
- A19 Temperature Control Less Enclosure (SPDT, Close Differential
- A19 Series Thermostat for Hazardous Locations
- A19 Series Coiled Bulb Space Thermostat
- A19 Thermostat for Portable Heaters (Chain Mount and Drop Cord Electrical Connection)
- A19 Thermostat for Portable Cooling Applications (Chain Mount and Drop Cord Electrical Connection)
- A19 Series Automatic Changeover with Strap-On Mounting
- A19D Series Surface Mounted Temperature Control
- A19 Flange Mounted Duct Thermostat
- A19 Series Fan or Cutout Control (Liquid Expansion Bulb)
- A19ANC-1 Temperature Control with Rainproof Enclosure
- A19 Agricultural/Industrial Thermostat with NEMA 4X Enclosure
- A19 Industrial Thermostat (Watertight and Dusttight)
- A19 Temperature Control with NEMA 4X Enclosure (Remote Bulb)
- A19 Water Chiller Control with Locked Cut-Out/Adjustable Cut-In
- A19 Defrost Duration and Fan Delay Control
- A25 Series Warm Air Limit Control with Manual Reset
- A70 Series Four-Wire, Two-Circuit Temperature Control
- A72 Series Two-Pole Heavy Duty Temperature Controls (Adjustable Differential)
- A72 Series Cooling Tower or Evaporative Condenser Controls (Single-Stage Temperature Control with Outdoor Enclosure)
- A72AA Coiled Bulb Space Thermostat (Cooling)
- Single-Stage Electronic Temperature Controls
- A421 Series Electronic Temperature Controls
- A421 Series Electronic Temperature Controls with Integral Power Cord
- A421 Series Electronic Temperature Controls with Off-Cycle Defrost
- A421 Series Electronic Temperature Controls with Integral Cycle Timer
- MR Series Defrost Control Modules
- MR4PMUHV Electronic Temperature/Defrost Control with Relay Pack
- Multi-Stage Electromechanical Temperature Controls
- A28 Series Two-Stage Temperature Control
- A28 Series Two-Stage Flange Mounted Duct Thermostat
- A28 Two-Stage Industrial Thermostat (Watertight and Dusttight)
- A28 Two-Stage Temperature Control with Weatherproof Enclosure
- A28 Two-Stage Agricultural Thermostat with NEMA 4X Enclosure
- A36 Series Four-Stage Remote Bulb Thermostats
- S26 Series Switching Subbase
- T22/T25/T26 Series Line Voltage Wall Thermostat (Heating, Cooling, or Heating and Cooling)
- Typical Wiring Diagrams and Electrical Ratings for Line Voltage Thermostats
- T23 Series Fan Coil Thermostat (with Fan and System Selectors)
- T28 Series Fan Coil Thermostat (with or without Fan Selector Switches)
- T46 Series Fan Coil Thermostat
- Multi-Stage Electronic Temperature Controls
- Temperature Control Sensors and Accessories
- Standard Electromechanical Pressure Controls
- P10 Series Low Pressure Control
- P20 Series Air Conditioning/Pressure Cutout Control
- P29 Series Low Pressure Control with Time Delay
- P47 Series Steam Pressure Limit Control
- P67 Series Low Pressure Control
- P70, P72 Approximate Low Pressure Settings for Typical Applications
- P70, P72, and P170 Series Controls for Low Pressure Applications
- P70, P72, and P170 Series Controls for High Pressure Applications
- P70, P72, and P170 Series Controls for Dual Pressure Applications
- Single-Stage Electronic Pressure Controls
- Electromechanical Lube Oil and Differential Pressure Controls
- Electronic Lube Oil and Differential Pressure Controls
- Pressure Sensors and Accessories
- Refrigerant Sensors/Monitors
- Liquid Level and Flow Controls
- Motor Speed Controls
- Valves and Valve Accessories
- V43/V243 Series Pressure-Actuated Water-Regulating Valves
- V46 Series Pressure Actuated Water Regulating Valve
- V46N Series Reverse Acting Valve
- V46 Series Valve Sizing Information-90% Open Method
- V46 Series Valve Dimensions
- V47 Series Temperature Actuated Modulating Valve
- V47N Series Reverse Acting Valve
- V48 Series Three-Way Water Regulating Valve
- V146 Series Two-Way Pressure-Actuated Water-Regulating Valves
- V148 Series Three-Way Pressure-Actuated Water-Regulating Valves
- V246 Series Two-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants
- V248 Series Three-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants
- STT Water Valve Renewal Kit for V46, V47, and V48 Series Valves
- Companion Flanges and Gaskets for V43, V46, and V47 Series Valves
- Relays and Transformers
- System 450 Control Series
- System 450™ Series Modular Controls
- System 450™ Series Control Module with Network Communications
- System 450™ Reset Control Modules with Real-Time Clock and Relay Output
- System 450™ Control Modules with Analog Output
- System 450™ Control Modules with Relay Output
- System 450™ Control Module with Hybrid Analog Output
- System 450™ Expansion Modules with Analog Output
- System 450™ Expansion Modules with Relay Output
- System 450™ Power Module
- System 450™ Compatible Sensors, Transducers, and Accessories
- Cross-Reference
- HVACR Product Offerings
- Sales Contact Information
The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2015 Johnson Controls, Inc. www.johnsoncontrols.com
R-97
P70, P72, and P170 Series Controls for High Pressure Applications
(Continued)
Standard Electromechanical Pressure Controls
Models for High Pressure Non-Corrosive Refrigerants
2
P70AA-2C SPST Open Low 0 to 150 (0 to 1,034) Minimum 10 (69); Maximum 70 (483) 36 in. Cap. with 1/4 in. Flare Nut 325 psig
(2,241 kPa)
P170AA-2C 1/4 in. External Flare Connector
P70AA-400C 100 to 470
(689 to 3,241)
Minimum 35 (241); Maximum 200 (1,379) 36 in. Cap. with 1/4 in. Flare Nut 690 psig
(4,757 kPa)
P170AA-400C 1/4 in. External Flare Connector
P70CA-400C
1
SPST Open High 200 to 610
(1,379 to 4,206)
Minimum 60 (414); Maximum 150 (1,034) 36 in. Cap. with 1/4 in. Flare Nut
P170CA-400C
1
1/4 in. External Flare Connector
P70DA-400C
1
Manual Reset Lockout 36 in. Cap. with 1/4 in. Flare Nut
P170DA-400C
1
1/4 in. External Flare Connector
Ammonia Compatible Models
P70AA-119C SPST Open Low 50 to 300 (345 to 2,068) Minimum 20 (138); Maximum 120 (827)
1/4 in. SS Internal NPT
400 psig
(2,758 kPa)
P70CA-5C
1
SPST Open-High
50 to 500
(345 to 3,448)
Minimum 60 (414); Maximum 150 (1,034)
525 psig
(3,620 kPa)
P70DA-2C
1
Manual Reset Lockout
P70KA-7C Four-wire, Two-circuit
Line-M1 Close-high
Line-M2 Open High
1. UL Listed as refrigeration pressure limiting controls
2. Compatible with R410A refrigerant.
Selection Chart (Part 2 of 2)
Product Code
Number
Switch
Action
Range
psi (kPa)
Differential
psi (kPa)
Pressure
Connection
Max. Working
Pressure
Note: To order models not listed in the selection chart, please contact
Johnson Controls/PENN Refrigeration Application Engineering at 1-800-275-5676.
Technical Specifications
Single Pressure Controls Switch Action, Low Event, High Event, and Models
Switch and Action Low Event High Event Models
SPST Open Low Cut-Out (Opens Line to M1) Cut-In (Closes Line to M1) P70A, P70B, P170A
SPST Open High Cut-In (Closes Line to M1) Cut-Out (Opens Line to M1) P70C, P70D, P170C,
P170D
SPDT Opens 1 to 2 and closes 1 to 3 Closes 1 to 2 and Opens 1 to 3 P70E, P70F
Four-wire, Two-circuits,
1 N.O., 1 N.C. Open Low
Cut-Out
(Opens M2 to Line and Closes M1 to Line)
Cut-In
(Closes M2 to Line and Opens M1 to Line)
P70G, P70H
Four-wire, Two-circuits,
1 N.O., 1 N.C. Open High
Cut-In
(Closes M2 to Line and Opens M1 to Line)
Cut-Out
(Opens M2 to Line and Closes M1 to Line)
P70J, P70K, P170K
DPST Open Low Cut-Out (Opens M1 to Line and M2 to Line) Cut-In (Closes M1 to Line and M2 to Line) P72A, P72B
DPST Open High Cut-In (Closes M1 to Line and M2 to Line) Cut-Out (Opens M1 to Line and M2 to Line) P72C, P72D