Brochure
Table Of Contents
- Refrigeration Products Catalog, PUBL-5510
- Product Catagories
- Table of Contents
- Code Number Index
- Single-Stage Electromechanical Temperature Controls
- A11 Series Low Temperature Cutout Controls
- A19 Series Remote Bulb Control
- A19 Series High Range Temperature Control
- A19 Series Thermostat for Crop Drying
- A19 Series Hot Water Temperature Control (Well Immersion)
- A19 Temperature Control Less Enclosure (SPDT, Close Differential
- A19 Series Thermostat for Hazardous Locations
- A19 Series Coiled Bulb Space Thermostat
- A19 Thermostat for Portable Heaters (Chain Mount and Drop Cord Electrical Connection)
- A19 Thermostat for Portable Cooling Applications (Chain Mount and Drop Cord Electrical Connection)
- A19 Series Automatic Changeover with Strap-On Mounting
- A19D Series Surface Mounted Temperature Control
- A19 Flange Mounted Duct Thermostat
- A19 Series Fan or Cutout Control (Liquid Expansion Bulb)
- A19ANC-1 Temperature Control with Rainproof Enclosure
- A19 Agricultural/Industrial Thermostat with NEMA 4X Enclosure
- A19 Industrial Thermostat (Watertight and Dusttight)
- A19 Temperature Control with NEMA 4X Enclosure (Remote Bulb)
- A19 Water Chiller Control with Locked Cut-Out/Adjustable Cut-In
- A19 Defrost Duration and Fan Delay Control
- A25 Series Warm Air Limit Control with Manual Reset
- A70 Series Four-Wire, Two-Circuit Temperature Control
- A72 Series Two-Pole Heavy Duty Temperature Controls (Adjustable Differential)
- A72 Series Cooling Tower or Evaporative Condenser Controls (Single-Stage Temperature Control with Outdoor Enclosure)
- A72AA Coiled Bulb Space Thermostat (Cooling)
- Single-Stage Electronic Temperature Controls
- A421 Series Electronic Temperature Controls
- A421 Series Electronic Temperature Controls with Integral Power Cord
- A421 Series Electronic Temperature Controls with Off-Cycle Defrost
- A421 Series Electronic Temperature Controls with Integral Cycle Timer
- MR Series Defrost Control Modules
- MR4PMUHV Electronic Temperature/Defrost Control with Relay Pack
- Multi-Stage Electromechanical Temperature Controls
- A28 Series Two-Stage Temperature Control
- A28 Series Two-Stage Flange Mounted Duct Thermostat
- A28 Two-Stage Industrial Thermostat (Watertight and Dusttight)
- A28 Two-Stage Temperature Control with Weatherproof Enclosure
- A28 Two-Stage Agricultural Thermostat with NEMA 4X Enclosure
- A36 Series Four-Stage Remote Bulb Thermostats
- S26 Series Switching Subbase
- T22/T25/T26 Series Line Voltage Wall Thermostat (Heating, Cooling, or Heating and Cooling)
- Typical Wiring Diagrams and Electrical Ratings for Line Voltage Thermostats
- T23 Series Fan Coil Thermostat (with Fan and System Selectors)
- T28 Series Fan Coil Thermostat (with or without Fan Selector Switches)
- T46 Series Fan Coil Thermostat
- Multi-Stage Electronic Temperature Controls
- Temperature Control Sensors and Accessories
- Standard Electromechanical Pressure Controls
- P10 Series Low Pressure Control
- P20 Series Air Conditioning/Pressure Cutout Control
- P29 Series Low Pressure Control with Time Delay
- P47 Series Steam Pressure Limit Control
- P67 Series Low Pressure Control
- P70, P72 Approximate Low Pressure Settings for Typical Applications
- P70, P72, and P170 Series Controls for Low Pressure Applications
- P70, P72, and P170 Series Controls for High Pressure Applications
- P70, P72, and P170 Series Controls for Dual Pressure Applications
- Single-Stage Electronic Pressure Controls
- Electromechanical Lube Oil and Differential Pressure Controls
- Electronic Lube Oil and Differential Pressure Controls
- Pressure Sensors and Accessories
- Refrigerant Sensors/Monitors
- Liquid Level and Flow Controls
- Motor Speed Controls
- Valves and Valve Accessories
- V43/V243 Series Pressure-Actuated Water-Regulating Valves
- V46 Series Pressure Actuated Water Regulating Valve
- V46N Series Reverse Acting Valve
- V46 Series Valve Sizing Information-90% Open Method
- V46 Series Valve Dimensions
- V47 Series Temperature Actuated Modulating Valve
- V47N Series Reverse Acting Valve
- V48 Series Three-Way Water Regulating Valve
- V146 Series Two-Way Pressure-Actuated Water-Regulating Valves
- V148 Series Three-Way Pressure-Actuated Water-Regulating Valves
- V246 Series Two-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants
- V248 Series Three-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants
- STT Water Valve Renewal Kit for V46, V47, and V48 Series Valves
- Companion Flanges and Gaskets for V43, V46, and V47 Series Valves
- Relays and Transformers
- System 450 Control Series
- System 450™ Series Modular Controls
- System 450™ Series Control Module with Network Communications
- System 450™ Reset Control Modules with Real-Time Clock and Relay Output
- System 450™ Control Modules with Analog Output
- System 450™ Control Modules with Relay Output
- System 450™ Control Module with Hybrid Analog Output
- System 450™ Expansion Modules with Analog Output
- System 450™ Expansion Modules with Relay Output
- System 450™ Power Module
- System 450™ Compatible Sensors, Transducers, and Accessories
- Cross-Reference
- HVACR Product Offerings
- Sales Contact Information
The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2015 Johnson Controls, Inc. www.johnsoncontrols.com
R-92
Repair Information
If the P70, P72, and P170 Series Controls
for Low Pressure Applications fail to
operate within their specifications, replace
the units.
For a replacement control,
contact the nearest Johnson
Controls®
representative.
P70, P72, and P170 Series Controls for Low Pressure Applications
Description
The P70, P72, and P170 Controls for low
pressure applications are designed primarily
for low pressure cut-out control, pump-down
control, and capacity control on commercial
refrigeration and air conditioning applications.
These controls are available in several
pressure ranges and are compatible with
most common refrigerants. They may also be
used on other non-corrosive fluid
applications. Ammonia-compatible models
are also available.
Controls also are available in several different
electrical ratings and switch configurations.
The P72 models provide direct control of
208 to 240 volt single-phase motors up to
3 horsepower, and 208 to 220 volt
three-phase motors up to 5 horsepower.
Refer to the P70, P72, and P170 Series
Controls for Low Pressure Applications
Product Bulletin (Part No. 24-7664-2608) for
important product application information.
Features
• all-steel case and cover built to provide
long lasting, rugged protection for internal
components
• sight-set calibrated pressure adjustment
displays a visible pressure scale, fully
adjustable through the range without
removing the cover (on NEMA 1 enclosure
models)
• MICRO-SET™ differential option allows
for precise control on critical low pressure
applications
• manual reset lockout option provides
trip-free low pressure lockout that cannot
be overridden or reset until pressure
returns to specified level
• limited knob adjustment option restricts
control adjustment ranges and deters
tampering and over-adjustment
Applications
NEMA 1 enclosures are standard on most
models.
• P70A and P170A models with
single-pole, single-throw (SPST)
Open Low switch action are the most
popular models, and are typically used for
low pressure cut-out and pump-down
control.
• P70 and P170 models are also available
with SPST Open High switch action, and
are typically used for capacity control.
Models with single-pole, double-throw
(SPDT) or four-wire, two-circuit switch
action allow users to install alarm devices
or other control circuits.
• P72 models have a double-pole,
single-throw (DPST) switch with
load-carrying contacts that can provide
direct control of 208 to 240 V single-phase
motors up to 3 horsepower, and 208 to 220
V 3-phase motors up to 5 horsepower. See
the DPST Electrical Ratings (P72A, B, C,
and D Models) that follow.
P70AB-12 MICRO-SET
Low Pressure Control
Standard Electromechanical Pressure Controls
Code No. LIT-1900170