The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2015 Johnson Controls, Inc. www.johnsoncontrols.com
R-193
System 450™ Series Modular Controls (Continued)
System 450 Control Series
The Control Modules with Communications have additional
features:
Ethernet communication capability through a built-in web server
(Ethernet Control Modules only) allows you to monitor your control
system status and set up or change the parameters by means of
a direct Ethernet cable connection, through a LAN connection, or
over the Internet. The built in web server delivers user-friendly web
pages to client browsers on a desktop, laptop, tablet, or smart
device.
The Web page server on Ethernet communication modules
provides a simple, intuitive web interface for easy remote
monitoring, setup, adjustment and remote monitoring of your
control systems across Ethernet networks.
RS485, RTU-compliant Modbus® network communication
capability (Modbus control modules only) enables a head-end
RS485 Modbus master controller to read and write control system
status and setup parameters to the System 450 Modbus
communication control module.
Password protection for local access (Ethernet and Modbus
control modules only) and password protection for remote access
(Ethernet control module only) deters unauthorized changes to the
control system settings, but allows local and remote monitoring of
your control system status.
Analog output signal limiting features (communication control
modules only) allow you to select the rate and condition range at
which the control updates the analog output signal, potentially
reducing wear on the controlled equipment.
Binary input with time delay (communication control modules only)
allows you to use an external set of dry contacts and selectable
time delays to control relay outputs.
Applications
You can create a wide variety of custom, application-specific control
systems with System 450 modules. The following are some common
control application examples:
Temperature control
Pressure control
Humidity control
Multipurpose control
Reset and setback control
High input-signal selection
Differential control
Temperature Control
Temperature monitoring and alarming
On/Off staged control of boilers and chillers
Proportional stage control of boilers and chillers
Boiler and chiller pump control
Heating and cooling control with deadband
Floating temperature control of damper and valve actuators
Cooling tower fan speed/stage control based on water
temperature
Supply, make-up, and mixed air temperature control
Temperature actuated valve control
Supply and make-up air damper and fan control
Condenser fan staging or speed control based on condenser
temperature
Refrigerant Pressure Control
Condenser fan cycling and stage control
Multispeed condenser fan control
Floating pressure control of damper and valve actuators
Condenser fan speed and damper control
High and low pressure cutout control
Staged compressor control
Cooling tower fan speed control based on high-side pressure
Direct speed control of electronically commutated (EC) condenser
fan motors (C450CPW-100 model)
Other Pressure Control
Relief damper and fan control for building pressurization
Constant static pressure control
Humidity Control
On/Off humidification and dehumidification control
Proportional humidification and dehumidification control
Multistage humidification and dehumidification control
Humidity monitoring and alarming
Multipurpose Control
Temperature and pressure based refrigeration rack control
Temperature and humidity control of wine cellars and greenhouses
Temperature, humidity, and static pressure control of clean rooms
and greenhouses
Dehumidification with reheat control
Reset Control
Boiler supply water temperature reset control based on outside air
temperature
Chiller supply water temperature reset control based on outside air
temperature
VAV zone temperature control based on outside air temperature
Humidity reset based on outside air temperature
Staged applications with runtime balancing
Real-time Occupied/Unoccupied Setback
High Input Signal Selection
Pressure-based fan speed or fan cycling control on multi-circuit
condensers
Temperature-based fan speed or fan cycling control on
multi-circuit condensers
Differential Control
Air and fluid pump-flow monitoring and alarming
Air and fluid filter status monitoring and alarming
Chiller barrel flow monitoring, control, and alarming
Solar air and water heating applications
Note: Communications modules add network communication to any
application of your choosing, except those requiring reset, setback, or
EC motor control.
Repair Information
If a System 450 module fails to operate within its specifications,
replace the module. For a replacement module, contact your
Johnson Controls® representative.