Brochure
Table Of Contents
- Refrigeration Products Catalog, PUBL-5510
- Product Catagories
- Table of Contents
- Code Number Index
- Single-Stage Electromechanical Temperature Controls
- A11 Series Low Temperature Cutout Controls
- A19 Series Remote Bulb Control
- A19 Series High Range Temperature Control
- A19 Series Thermostat for Crop Drying
- A19 Series Hot Water Temperature Control (Well Immersion)
- A19 Temperature Control Less Enclosure (SPDT, Close Differential
- A19 Series Thermostat for Hazardous Locations
- A19 Series Coiled Bulb Space Thermostat
- A19 Thermostat for Portable Heaters (Chain Mount and Drop Cord Electrical Connection)
- A19 Thermostat for Portable Cooling Applications (Chain Mount and Drop Cord Electrical Connection)
- A19 Series Automatic Changeover with Strap-On Mounting
- A19D Series Surface Mounted Temperature Control
- A19 Flange Mounted Duct Thermostat
- A19 Series Fan or Cutout Control (Liquid Expansion Bulb)
- A19ANC-1 Temperature Control with Rainproof Enclosure
- A19 Agricultural/Industrial Thermostat with NEMA 4X Enclosure
- A19 Industrial Thermostat (Watertight and Dusttight)
- A19 Temperature Control with NEMA 4X Enclosure (Remote Bulb)
- A19 Water Chiller Control with Locked Cut-Out/Adjustable Cut-In
- A19 Defrost Duration and Fan Delay Control
- A25 Series Warm Air Limit Control with Manual Reset
- A70 Series Four-Wire, Two-Circuit Temperature Control
- A72 Series Two-Pole Heavy Duty Temperature Controls (Adjustable Differential)
- A72 Series Cooling Tower or Evaporative Condenser Controls (Single-Stage Temperature Control with Outdoor Enclosure)
- A72AA Coiled Bulb Space Thermostat (Cooling)
- Single-Stage Electronic Temperature Controls
- A421 Series Electronic Temperature Controls
- A421 Series Electronic Temperature Controls with Integral Power Cord
- A421 Series Electronic Temperature Controls with Off-Cycle Defrost
- A421 Series Electronic Temperature Controls with Integral Cycle Timer
- MR Series Defrost Control Modules
- MR4PMUHV Electronic Temperature/Defrost Control with Relay Pack
- Multi-Stage Electromechanical Temperature Controls
- A28 Series Two-Stage Temperature Control
- A28 Series Two-Stage Flange Mounted Duct Thermostat
- A28 Two-Stage Industrial Thermostat (Watertight and Dusttight)
- A28 Two-Stage Temperature Control with Weatherproof Enclosure
- A28 Two-Stage Agricultural Thermostat with NEMA 4X Enclosure
- A36 Series Four-Stage Remote Bulb Thermostats
- S26 Series Switching Subbase
- T22/T25/T26 Series Line Voltage Wall Thermostat (Heating, Cooling, or Heating and Cooling)
- Typical Wiring Diagrams and Electrical Ratings for Line Voltage Thermostats
- T23 Series Fan Coil Thermostat (with Fan and System Selectors)
- T28 Series Fan Coil Thermostat (with or without Fan Selector Switches)
- T46 Series Fan Coil Thermostat
- Multi-Stage Electronic Temperature Controls
- Temperature Control Sensors and Accessories
- Standard Electromechanical Pressure Controls
- P10 Series Low Pressure Control
- P20 Series Air Conditioning/Pressure Cutout Control
- P29 Series Low Pressure Control with Time Delay
- P47 Series Steam Pressure Limit Control
- P67 Series Low Pressure Control
- P70, P72 Approximate Low Pressure Settings for Typical Applications
- P70, P72, and P170 Series Controls for Low Pressure Applications
- P70, P72, and P170 Series Controls for High Pressure Applications
- P70, P72, and P170 Series Controls for Dual Pressure Applications
- Single-Stage Electronic Pressure Controls
- Electromechanical Lube Oil and Differential Pressure Controls
- Electronic Lube Oil and Differential Pressure Controls
- Pressure Sensors and Accessories
- Refrigerant Sensors/Monitors
- Liquid Level and Flow Controls
- Motor Speed Controls
- Valves and Valve Accessories
- V43/V243 Series Pressure-Actuated Water-Regulating Valves
- V46 Series Pressure Actuated Water Regulating Valve
- V46N Series Reverse Acting Valve
- V46 Series Valve Sizing Information-90% Open Method
- V46 Series Valve Dimensions
- V47 Series Temperature Actuated Modulating Valve
- V47N Series Reverse Acting Valve
- V48 Series Three-Way Water Regulating Valve
- V146 Series Two-Way Pressure-Actuated Water-Regulating Valves
- V148 Series Three-Way Pressure-Actuated Water-Regulating Valves
- V246 Series Two-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants
- V248 Series Three-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants
- STT Water Valve Renewal Kit for V46, V47, and V48 Series Valves
- Companion Flanges and Gaskets for V43, V46, and V47 Series Valves
- Relays and Transformers
- System 450 Control Series
- System 450™ Series Modular Controls
- System 450™ Series Control Module with Network Communications
- System 450™ Reset Control Modules with Real-Time Clock and Relay Output
- System 450™ Control Modules with Analog Output
- System 450™ Control Modules with Relay Output
- System 450™ Control Module with Hybrid Analog Output
- System 450™ Expansion Modules with Analog Output
- System 450™ Expansion Modules with Relay Output
- System 450™ Power Module
- System 450™ Compatible Sensors, Transducers, and Accessories
- Cross-Reference
- HVACR Product Offerings
- Sales Contact Information
The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2015 Johnson Controls, Inc. www.johnsoncontrols.com
R-127
F59 Series Sump Pump Switch
Code No. LIT-1922325
Description
The F59 Series Controls are designed to start
an electric motor on liquid level rise and stop
the motor on liquid level drop. The control cuts
in when upper weight is submerged
approximately halfway, and cuts out when
lower weight is approximately half-exposed.
Each switch includes 36 in. cable and
two weights.
Refer to the F59 Series Liquid Level Switch
for Sump Operations Product Bulletin
(LIT-125215) for important product
application information.
Features
F59D-5 is equipped with a power cord and a
piggyback style plug. The external prongs
plug into the wall outlet, and the sump pump
cord plugs into the internal end of the plug.
Applications
Use for On/Off control of sump pumps.
Technical Specifications
Electrical Ratings
Volts Horsepower
F59A-1
120 VAC 1 hp
240 VAC 1 hp
32 VDC 1/4 hp
F59A-2
120 VAC 1 hp
240 VAC 1 hp
32 VDC 1/4 hp
F59D-5
120 VAC 1/2 hp
F59H-1
120 VAC 1 hp
240 VAC 1 hp
32 VDC 1/4 hp
Type F59A, F59H
Action on Rise
in Liquid Level
Line
M2
Line
M1
f59.eps
F59 Series Action Diagram
Selection Charts
Product Code
Number
Contact
Action
Mounting Range
Adjuster
F59A-1C Double-Pole,
Single-Throw
(DPST)
External mounting bracket Drop cord wiring
F59A-2C DPST External mounting – includes universal
mounting bracket and 24 in. strap for
quick, easy mounting on the motor, on the
pedestal or on the discharge pipe.
Drop cord wiring
F59H-1C DPST External mounting bracket Conduit wiring –7/8 in.
conduit openings in case
Replacement Parts
Product Code
Number
Replacement Weight Kit for F59 Series
WGT11A-600R Two Weights (Floats), 40 in. Plastic Cable, Weights with 3 in. Polyethylene Cable
WGT11A-604R Two Weights (Floats), 36 in. Monel Wire, Two Float Support Plates,
Weights with 3 in. Monel Cable
F59H-1 Sump Pump Switch
F59A-2 Sump Pump Switch
Liquid Level and Flow Controls