Instructions / Assembly

– 2 –
331921-000
INTERIOR/EXTERIOR S.S. SHIELD
(PART OF VENT TERMINAL)
CONNECTOR-FLEX DUCT TO VENT
TERMINAL (PART OF VENT DUCT)
3 in. CLAMP
FLEX DUCT
TRANSITION PIECE WATER
HEATER TO FLEX DUCT
(PART OF FLEX DUCT)
6 in. CLAMP
VENT TERMINAL
SCREEN
JW6 F307V
WATER HEATER
Figure 1. Vent Component Identification
EXHAUST
DUCT KIT
DUCT
VENT
TERMINAL
63320 - 5’ 63377
6337663321 - 10’ 63378
63322 - 20’ 63379
NOTE 1
APPLY CAULKING
ON OUTSIDE
VENT TERMINATION
DEVICE
SCREEN
12 in.
ANTICIPATED MAX.
SNOW LINE
GRADE LEVEL
5-1/8 in.
INSULATION
BLOCKING
NO INSULATION
IN THIS SPACE
BLOCKING
3 ft.
MAX.
MAX. DISTANCE BETWEEN
SUPPORTS 3 ft. ON
LONGER RUNS
DO NOT ALTER ANY
VENT COMPONENTS.
TRANSITION PIECE
WATER HEATER TO
FLEX DUCT (PART
OF FLEX DUCT)
SEE DETAIL
Figure 4.
JW6 F307V
WATER HEATER
NOTE 1.
IF THE EXTERIOR FACE IS ALUMINUM
OR VINYL SIDING OR ANY OTHER
SIDING WHICH MAY BE DISCOLORED OR
AFFECTED BY FLUE GASES, A METAL
SHIELD OF AT LEAST 30 in. x 30 in. , MUST
BE PROVIDED TO COVER THIS WALL
SECTION.
Figure 2. Installation Details