Filling The Water Heater
• Avoid water heater damage.
• Fill tank with water before operating.
Property Damage Hazard
CAUTION
Do not insert the power cord into the electrical receptacle until
all the following steps have been completed.
1. Make sure the drain valve is closed.
2. Open all hot water faucets served by the system to allow
air to escape from the tank.
3. Open the cold water inlet valve.
Note: When filling, avoid water leakage. Do not allow the
insulation of the water heater to get wet as water can reduce
the effectiveness of the insulation.
4. When an uninterrupted stream of water, without apparent
air bubbles, flows from the open hot water faucets, the
tank is full.
5. Close the hot water faucets and check the system for
leaks. Repair as required and retest.
6. Connect a hose to the drain valve and route to a suitable
drain.
7. Open the drain valve and let water run to flush out
any foreign matter that may have entered the system.
Continue flushing until clean water flows.
8. Close the drain valve, disconnect the hose, ensure the
drain valve does not drip and re-fill the tank.
Installation Checklist
Have the safety precautions described in the manual
been implemented?
Does the oil piping conform to the recommendations of
your Oil Supply Company?
Has the oil piping been tested for leaks?
Is the clearance between the water heater and combus-
tible construction as per specifications?
Is the water piping correctly connected? Are you certain
that there are no leaks?
Is the water heater filled with water?
Is the cold water supply valve open?
Is the flue pipe installed properly and are the vertical
and horizontal runs properly supported?
Is the draft regulator intake opening unobstructed?
Is the T&P valve installed? Are the drain pipe (if
installed) and T&P valve unobstructed?
Is a drain pan installed (if required) with a proper over-
flow pipe, directed to a drain?
Have you taken steps to prevent water damage in case
of leaks?
Does the area around the water heater have adequate
ventilation?
Air moving device does not create negative pressure?
Flammable vapors and materials are not placed in the
proximity of the water heater?
If the answer to all the above is “Yes”, proceed with the
"Startup" instructions.
IV) OPERATION
Startup
CAUTION:
Read before proceeding. If you do not follow
these instructions exactly, a fire or explosion
may result, causing property damage, per-
sonal injury or loss of life.
DO NOT ATTEMPT TO START BURNER IF ANY OF THE
FOLLOWING CONDITIONS EXIST:
1. Excess oil has accumulated.
2. The unit is full of vapors.
3. The combustion chamber is hot.
Note: Refer to the instruction manual supplied with the burner
for installation, start up and adjustment.
After the installation is finished and the installation checklist
completed, proceed as follows:
1. Set the draft regulator for full draft.
2. Turn on oil at the tank. Adjust the air band on the burner
according to the instructions provided by the burner
manufacturer.
Printed on 7/3/2019 7:21 AM CT