User manual

Installation under a counter
The appliance can be installed as freestanding or
below the kitchen counter with correct space
(see picture).
> 850 mm
600 mm
600 mm
The load door reversal
The load door can be installed by the user in the
opposite side. It can help to easily put and
remove the laundry or if there is a limit to install
the appliance. (see separate leaflet).
Electrical connection
Connect the appliance to a grounded socket.
Refer to the applicable electrical
requirements.
Make sure that the electrical data on the
rating plate agrees with the power supply.
Always use a correctly installed shockproof
socket.
Do not use multiple plugs and extension
cables. There is a risk of fire.
All replacements of power supply cable must
be carried out by our Service.
Make sure not to squash or cause damage to
the mains plug and cable behind the
appliance.
Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
The plug must be dry.
The data about mains voltage, type of current
and the necessary fuse are on the rating plate
and in the “TECHNICAL INFORMATION”
chapter. The rating plate is behind the load door
(see the “PRODUCT DESCRIPTION” chapter).
The appliance has a power supply cable with
plug fitted with 13 A fuse. If necessary, replace
the fuse in the plug by 13 A ASTA BS 1363/A
approved fuse.
The wires in the power supply cable are
coloured as follow:
A
B
C
D
A)
green and yellow - ground — earth (E)
B)
brown - live (L)
C) cord clamp
D)
blue - neutral (N)
The green and yellow coloured wire must be
connected to the terminal with E mark or the
ground
mark or the green and yellow
coloured terminal.
The blue coloured wire must be connected to
the terminal N or black coloured .
The brown coloured wire must be connected to
the terminal L or red coloured .
The wires of the cable must be no cut or stray
strands of wire present and the cable clamp
must be secure over the outer sheath.
Permanent connection
The necessary condition of permanent
connection is to install a double-pole isolating
switch directly on the supply terminals.
The type of switch must be correct for the
necessary load and must align with applicable
electrical requirements.
30 Tumble Dryer user manual