User manual
1. Turn the programme selector to any
programme.
2.
Press simultaneously the Anti-crease
and Start/Pause buttons and hold down
for approx. 5 seconds.
3.
Press the Start/Pause button until you
set desired level:
the LED Full tank low conductivity
<300 µS/cm
the LED Filter medium conductivity
300-600 µS/cm
the LED Condenser high conductivity
>600 µS/cm
4. To memorize setting press simultaneously
the Anti-crease and Start/Pause
buttons or turn knob to Off position
18