User Manual

Installation Instructions
CED,TX13067,2595 –19–18NOV99–3/5
Record vehicle hours, date and time of synchronization
on DeereTrax
Installation Record.
When DeereTrax Installation Record is complete Fax
it to the number on the record.
To synchronize the communications controller:
1. Move the machine outdoors with no electrical wires
or metal structures directly overhead.
2. Key switch ON. Engine OFF.
CED,TX13067,2595 –19–18NOV99–4/5
T125457B –UN–23NOV99
1—GPS/ENG RUN LED Light
2—CELL LED Light
3. Both LED lights (1 and 2) will come ON for 1—5
seconds, indicating power is present at the
communications controller.
LED lights may go OFF indicating no cellular service or
GPS lock.
CED,TX13067,2595 –19–18NOV99–5/5
T128066B –UN–03FEB00
LED Lights and Diagnostic Connector
1—GPS/ENG RUN LED Light and CELL Light
2—Diagnostic Connector
4. Wait up to ten minutes for both LED lights to come
ON.
If lights fail to come ON after ten minutes, see Problem
Diagnosis.
5. After both lights come ON, disconnect diagnostic
connector (2), wait more than six seconds.
6. Connect diagnostic connector.
7. Watch CELL LED light (1).
It must go OFF within one minute, then back ON.
8. When CELL LED light comes back ON, system is OK.
9. If CELL LED light does NOT come back ON, go to
Problem Diagnosis.
10. Complete the DeereTrax Installation Record and Fax
to the number listed on the sheet.
DeereTrax (13APR00)
38
Installation Instructions
041300
PN=40
P R O O F P R O O F