Product Manual

22
CAUTION! ALWAYS FOLLOW THE SAFETY REGULATIONS
The direction of rotation must be checked each time a new installation is carried out.
Proceed as follows:
1. Place the pump on a at surface;
2. Start the pump and stop it immediately;
3. Carefully observe the kick-back on starting, looking at the pump from above. TIf the direction of
rotation is correct, the upper cap will turn counter-clockwise as indicated by the arrows in the
drawing (Fig. 2). .
If it is not possible to check as described above because the pump is already installed, check as fol-
lows:
1. Start the pump and observe the water ow rate.
2. Stop the pump, switch off the power and invert two phases on the supply line.
3. Restart the pump and check the water ow rate again.
4. Stop the pump.
The correct direction of rotation is the one that gives the higher ow rate.
9 START-UP
9.1• Turn the differential magnetothermal switch upstream from the pump to position I (ON)
and wait until the water comes out of the delivery pipe.
• If malfunctions are found, disconnect the pump from the power supply, turning the differential
magnetothermal switch to position 0 (OFF) and consult the chapter on “TROUBLESHOOTING”.
• The pump may be started and stopped:
- Manually by means of the differential magnetothermal switch upstream from the system.
- Automatically when water level rises, for versions with a oat switch.
Fig. 2
8.4 CHECKING THE DIRECTION OF ROTATION (for three-phase motors)
JONTRACT
JONTRACT 180-250-300-400-600
JONTRACT 550-750-1250-1500