Product Manual
30
-The characteristics and technical data are not binding. JMS reserves the right to make modications without notice. There-
fore weights, dimensions,performances and any other stated issues are indicative only and not binding
TECHNICAL DATA
JKIPPER
80 F
1~ Phase
3 ~ Phases
JKIPPER
150 F
1~ Phase
3 ~ Phases
JKIPPER
200 F
1~ Phase
3 ~ Phases
JKIPPER
300 F
1~ Phase
3 ~ Phases
JKIPPER
400 F
1~ Phase
3 ~ Phases
Electric connection/voltage
230 V/60 Hz
---
230 V/60 Hz
---
230 V/60 Hz
---
---
230 V/60 Hz
---
230 V/60 Hz
Power rating P1 (kW)
1,5
---
2,7
---
3,5
---
---
6,5
---
5,7
Current absorption (A)
13,2
---
12,0
---
15,5
---
---
21
---
21
Max. High head pressure(mt)
10 9,5 12,5 17 19
Max. capacity (I/min)
290 480 650 1100 1100
Max temp. of liquid (°C)
35° 35° 35° 35° 35°
Horizontal suction. (mm)
170 170 180 180 200
Max. submersion depth (mt)
5 5 5 5 5
N° of impellers
1 1 1 1 1
Electric cable (mt)
10 10 10 10 10
Foreign bod. aspir. up to ø (mm) 45 60 60 80 80
Discharge conn. thread DNM
2” NPT 2” 1/2 NPT 2” 1/2 NPT 3” NPT 3” NPT
Pump dimension BxD (mm)
217x381 260x473 260x473 278x515 278x641
Dim. imballaggio LxMxN(mm)
190x230x410 290x245x520 290x245x580 290x245x520 295x380x780
Weight (Kg)
11,5 19 22,5 23 39