1 GENERAL POINTS
Read this documentation carefully before installation.
Installation and functioning must comply with local and national safety regulations in force in
the country where the product is to be installed.
The entire operation must be carried out in a workmanlike manner.
Failure to comply with the safety regulations not only causes risk to personal safety and da-
mage to the equipment, but also invalidates any right to warranty assistance.
Keep this manual in a safe place for further consultation even after the rst
installation.
2 APPLICATIONS
These motor pumps (JENAX-JIVER-JIGER F-JKIPPER F) are t for moving clear water and
for pumping dirty water both in the presence of suspended solid bodies and brous parts
(only JENAX & JIVER), t for emptying settling beds and sewage collection wells. The parti-
cularly silent motor pump installed inside wells or tanks avoids all problems related to suction
and depriming.
The motor pump can be supplied with a oating switch should it be necessary to turn it off in
case of inadequate water level.
Keep this manual in a safe place for further consultation even after the rs.These pum-
ps cannot be used in swimming pools, ponds or tanks in which people are present, or
for pumping hydrocarbons (petrol, diesel fuel, fuel oils, solvents, etc.) in accordance
with the accident-prevention regulations in force.
N.B. : The liquid employed in the pump for lubricating the sealing device is not toxic, but it
could alter the water properties (in the case of pure water) if there were any leaks in the seal.
3 PUMPED FLUIDS
The machine has been designed and built for pumping water, free from explosive substances,
and solid particles or bres, with a density of 1 Kg/dm3 and a kinematic viscosity of 1mm2/s,
and chemically non-aggressive liquids.
4 TECHNICAL DATA AND USE LIMITATIONS
- Supply voltage: see electric data plate
- Absorbed power: see electric data plate
- Maximum ,working pressure: 1,5 Bar (JIGER F - JKIPPER F)
3,0 Bar (JENAX - JIVER)
- Pumped uid: clean, dirty, with solid, brous bodies, (only JIVER), not
aggressive.
- Degree of motor protection: IP 68
- Thermal class: F
- Liquid temperature range: from 0°C to 25°C with pump part. submerged
from 25°C to 35°C with pump fully submerged
- Maximum immersion: 5 metres
- Storage temperature: from -10°C to +35°C
- Noise level: noise level is contained within the limits envisaged by EC
Directive EC 89/392/CEE and subsequent modications.
-Motor constructions: in accordance with CEI 2-3 - CEI 61-69 (EN 60335-2-41)
standards.
70 dB