Instructions
Thank you for purchasing the ElectroVita Circulation Enhancer. Helps reduce stresses and aches with the amazing ElectroVita Circulation Enhancer from JML. Simply place your feet on the footpads, set the intensity level and sit back. Low frequency micro-currents safely stimulate the reflex points in your feet, waking up tired nerves, muscles and capillaries. Capillaries are the smallest of your bodies blood vessels and provide the exchange between cells and circulation.
Quick Start Guide For detailed operation of your ElectroVita™ Circulation Enhancer Electrical Stimulator please refer to the comprehensive instructions within this manual. To use the Circulation Enhancer immediately follow this 5 point quick start guide. 1. Remove your ElectroVita Circulation Massager from the packaging. Connect the DC adapter to a suitable mains outlet and plug the small DC socket into the device. 2.
Important safety information 1. Please read these instructions thoroughly before use. 2. Please check that you have all of the component parts as detailed in this user manual. 3. Take all parts out of the plastic bags and examine them to familiarise yourself with the components. Notes on Safety The icons and warning signs are indicated here for your safety and correct usage of the product as well as to prevent injuries and/or damage to properties.
Important safety information Danger This unit must not be used in combination with the following medical devices: t *OUFSOBMMZ USBOTQMBOUFE FMFDUSPOJD NFEJDBM EFWJDFT F H QBDFNBLFST t &MFDUSPOJD MJGF TVQQPSU FRVJQNFOU TVDI BT SFTQJSBUPST t &MFDUSPOJD NFEJDBM EFWJDFT BUUBDIFE UP UIF CPEZ TVDI BT FMFDUSPDBSEJPHSBQIT Using this unit with other electronic medical devices may cause erroneous operation of those devices.
Important safety information Do not use this unit on infants or people not capable of expressing their intentions. May cause an accident or ill health. Do not use this unit in places with high humidity such as bathrooms or while taking a bath or shower. You will receive a strong electrical shock. Do not use this unit while sleeping. The main unit may develop a malfunction, or the pad may move to an unexpected region and cause ill health. Do not use this unit while driving.
Important safety information Important information regarding Electro Magnetic Compatibility (EMC) With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation. Medical devices should also not interfere with other devices.
What is electronic nerve stimulation? INTENDED USE: Medical Purpose This Electronic Nerve Stimulator is intended to be used as a massager to relieve (muscle) pain, increase blood circulation, relax stiffness muscles, reduce swollen feet and ankles and fatigue. The massaging effect is achieved by electronic stimulation of the nerves through electrode pads placed on the skin or through the foot plates. Various massage regions and treatment programs can be selected.
Machine overview and part names Output for the feet Electrode Silicon Area for Foot Treatment LCD Display Screen Output for Body - for connecting Gel Pads (cable jack) for Body Massage Treatment Sole Massage Roller The EletroFlex Circulation Massager is also supplied with an AC/DC Adaptor (not illustrated) Adaptor Jack Cable connecting the Electrode Gel Pads and Device Built-in Ergonomic Carrying Handle Electrode Gel Pads to target speci c areas of pain and swelling Additional Sole Massage Roller (s
Functions and programmes Control Panel LCD showing the Intensity Level LCD showing the Intensity Level for feet – maximum 40 Levels BAND1 LCD showing the Timer for body – maximum 40 Levels BAND2 Min LCD showing the Program PROGRAM B Indication from 1 – 10 Modes F D A E G C A. To switch the unit on or off B. Choose from one of the 10 pre-programmed massage programs ~ Upward C. Choose from one of the 10 pre-programmed massage programs ~ Downward D.
Circulation Enhancer output wave forms Foot Electro Therapy Massage We will examine the operation in more detail later in your instructions but the principle is relatively easy to understand. There are two separate controls/channels, one for the feet, being band 1 and one for the pads being band 2.
ElectroVita output wave forms 11
How to operate For feet - BAND 1 In order to increase the conductivity we recommend that you dampen the soles of your feet. 1. Place your bare feet onto ElectroVita (do not wear socks). 2. Press (and hold down for 3 seconds) the on/off button, the LCD screen will light up in blue. The program will show 01 and both band shows 00, which means the device is in standby mode. (See Figure 3). 3. Select the program you wish to use, there are 10 different programs which are indicated on the LCD display.
How to operate For Body – BAND 2 Using the Gel Pads Connect the output wire to the gel pads. Connect the other end of the output wire to the output jack on ElectroFlex. Remove the protective film from the adhesive pads. Attach the gel pads to the skin. Press the on/off button for 3 seconds to turn on the unit andadjust the stimulating mode and output intensity to the desired level. (The display will show the mode and level that you selected and start to count down). 1.
How to operate Connect with the supplied AC/DC Power Adapter Plug the DC plug of the power supply into the socket on the side of ElectroVita (see Figure 10. Plug in power adaptor to a suitable wall socket. (Make sure that the input voltage of the wall socket is suitable for the supplied adaptor). Inserting Batteries If you want to use the ElectroVita with battery powerinstead of the supplied main adaptor, the battery compartment is located on the underside of the unit.
Cleaning Electrode Gel pad: t 8IFO OPU JO VTF TUPSF UIF FMFDUSPEF HFM QBET PO UIF QMBTUJD QBE QSPUFDUPST QSPWJEFE BU SPPN UFNQFSBUVSF t ,FFQ UIF FMFDUSPEF HFM QBET DMFBO BOE EVTU GSFF JO B ESZ MPDBUJPO keep away from oily or sticky objects. The life of the electrodes varies depending on skin conditions, storage, amount of use, type of stimulation, and stimulation site. Usage may be extended by carefully cleaning the gel surface with a damp cloth.
Troubleshooting and Maintenance SYMPTOM CAUSE ACTION Device will not turn on Batteries inserted in wrong direction Insert batteries in correct direction or check the battery is not discharged Check the connection of the adaptor jack is properly connected to the device and in the wall socket The adaptor is not connected to the device correctly Power turns o too soon Gel pads not attached correctly to the skin Power turns o while using massager If you are using the batteries operation, Fit three new
Troubleshooting and Maintenance Product Name ElectroVit a - Circulation Massager Electrical Stimulator Model BE109 Power Supply 4.5V DC or 3 x 1.5V Alkaline Batteries Type C* Supplier of Adaptor Golden Pro t Electronics Ltd. Adaptor Input 230V~ 50Hz 100mA Model Number of Adaptor SY-04010-BS Adaptor Input 230V~ 50Hz 100mA Adaptor Output 4.5V DC 100mA 0.45VA Battery Life Approx 1 Month: When used 25 minutes a day continuously Frequency Generation Approx. 1Hz to 80Hz Power Consumption 0.
Important Information Electro Magnetic Compatibility (EMC) 1. ElectroVita needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in the ACCOMPANYING DOCUMENTS. 2. Portable and mobile RF communications equipment can affect ElectroVita . 3.
Important Information 5. Guidance and Manufacturer’s Declaration – Electromagnetic Immunity The ElectroVita is intended for use in the electromagnetic environment specified below. The customer or the user of the ElectroVita should assure that it is used in such an environment.
Important Information Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environment Guidance Conducted RF IEC 61000-4-6 3V/ms 150kHz to 80MHz 3V/m Portable and mobile RF communications equipment should be used no closer to any part of the ElectroFlex, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance d = 1,2 㲋P Radiated RF IEC 61000-4-3 3V/ms 26MHz to 2.
Important Information 7. Recommended separation distances between portable and mobile RF communications equipment and the ELECTROVITA The ElectroVita is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
22
JML, Distributed by JML Unit 1 Eastside, Port of Tyne South Shields NE33 5SP info@JMLgroup.co.uk Product code: V0393 Freephone 0800 781 7831 | Web: www.JMLdirect.