Service Manual Owner's manual

SECTION 3 - TROUBLESHOOTING
3-22 – JLG Lift – 3120728
Will Only Drive A Short Distance
Overview Of Procedure
The following procedure will eliminate any problems found in the power circuit to the MC-1 controller box and also any
objectionable environmental conditions.
Check For These Obvious Conditions First:
• Is Battery Voltage 24 Volts? (Fully Charge Batteries)
Table 3-16. Only Drives A Short Distance
STEP ACTION SPEC YES NO
1. Is platform controller staying powered up when machine stops driv-
ing?
—Go to Step 2
Check the E-Stop
& Key Switch
Circuit
(Table 3-17)
2. Check the voltage out of the X101 connector, pin 5, to the power
relay pin 86. Check continuity at pin 85. 24 Volts Go to Step 3
Repair or Replace
Wires, or Problem
with MC-1 Box
3. Check the voltage from pin 87 on the power relay to the main con-
tactor. (Main contactor should be closed at this point)
24 Volts Go to Step 4
Repair or Replace
Wires or Relay
4. Check the voltage on the Yel/Red, 2-5 wire on the X101 connector,
pin A1, from the main contactor. 24 Volts Go to Step 5
Repair or Replace
Wires or Main
Contactor
5. What type of surface is machine being operated on? Is surface soft,
unstable or up a steep grade?
Machine will not
perform well on a
soft or unstable
surface, if motor
draw is over 70
amps, controller
will shut the
machine down.
( 7 LED Code)
Go to Step 6
6. Are brakes releasing when trying to drive?
—Go to Step 7
Repair/Replace
or Adjust Drive
Brakes
(See Procedure in
Service Manual)
7. Is drive system running free? No noise or dragging.
—Go to Step 8
Repair/Replace
or Adjust Drive
System
(See Procedure in
Service Manual)
8. Is machine being operated in an environment with high static
charge?
Machine may be
building static
charge in the MC-
1 controller,
which will make
the drive system
shut down.