Service Manual User guide

SECTION 6 - JLG CONTROL SYSTEM
6-80 – JLG Lift – 3121262
6.17 JIB SENSOR CALIBRATIONS
To calibrate the jib sensors, the analyzer must be in
access level 1. All jib sensors can be calibrated at one
time or each calibration can be performed on an individual
basis.
1. Position the Platform/Ground select switch to the
Ground position.
2. Plug the analyzer into the connector inside the
Ground control box.
3. Pull out the Emergency Stop switch and start the
engine.
4. The analyzer screen should read:
5. Use the arrow button to reach ACCESS LEVEL 2. Hit
Enter.
6. Enter the Access Code, 33271.
7. Use the right Arrow key to reach CALIBRATIONS. Hit
Enter.