Service Manual User guide
SECTION 6 - JLG CONTROL SYSTEM
6-60 – JLG Lift – 3121262
DATALOG:
ON XXXXhXXm Displays total controller on (EMS) time
ENGINE XXXXhXXm Display engine run time
DRIVE XXXXhXXm Displays total controller drive operation time
LIFT XXXXhXXm Displays total controller lift operation time
SWING XXXXhXXm Displays total controller swing operation time
TELE XXXXhXXm Displays total controller telescope operation time
MAX TEMP XXC Displays maximum measured ambient temp.
MIN TEMP XXC Displays minimum measured ambient temp.
MAX VOLTS XX.XV Displays maximum measured battery voltage
RENTAL XXXXhXXm Displays total controller operation time. NOTE: can be reset
ERASE RENTAL? Not available at Access Level 2.
ENTER resets rental data log time to zero.
VERSIONS:
GM SW PX.X Displays ground module software version
GM HW REV XXXX Displays ground module hardware revision
GM SN XXXXXX Displays ground module serial number
PM SW PX.X Displays platform module software version
PM HW REV XXXX Displays platform module hardware revision
PM SN XXXXXX Displays platform module serial number
CM SW PX.X Displays chassis module software version
BM SW PX.X Displays BLAM module software version
C PIN SW Displayed if cylinder moment load pin transmits software version.
C PIN SN Displayed if cylinder moment load pin transmits serial number.
ANALYZER VX.XXXX Displays Analyzer software version
Table 6-7. Machine Diagnostics Parameters
Diagnostics
Submenu
(Displayed on
Analyzer 1
st
Line)
Parameter (Displayed
on Analyzer 2
nd
Line)
Parameter Value
(Displayed on Analyzer 2
nd
Line)
Description