Service Manual User guide
SECTION 6 - JLG CONTROL SYSTEM
6-52 – JLG Lift – 3121262
BOOM:
U LIFT UP/DOWN XXX% Displays main lift joystick direction & demand
SWING RIGHT/LEFT XXX% Displays swing joystick direction & demand
QPRX1 ACTIVE/NOT ACTIVE Displays status of Q-Prox sensor in lift/swing joystick (Displayed if
JOYSTICK TYPE = 1)
QPRX2 ACTIVE/NOT ACTIVE Displays status of Q-Prox sensor in lift/swing joystick (Displayed if
JOYSTICK TYPE = 1)
LEVEL UP/DOWN XXX% Displays basket level switch direction & demand. NOTE: demand
is controlled by the pump pot
ROT. RIGHT/LEFT XXX% Displays basket rotate switch direction & demand. NOTE:
demand is controlled by the pump pot
U TELE IN/OUT XXX% Displays main telescope switch direction & demand. NOTE:
demand is controlled by the pump pot
T TELE IN/OUT XXX% Displays tower telescope switch direction & demand. NOTE:
demand is controlled by the pump pot
Not displayed if TOWER TELE=NO (machine digit = 0)
T LIFT UP/DOWN XXX% Displays tower lift switch direction & demand. NOTE: demand is
controlled by the pump pot
Not displayed if TOWER LIFT=NO (machine digit = 0)
JIB UP/DOWN XXX% Displays jib lift switch direction & demand. NOTE: demand is con-
trolled by the pump pot
Not displayed if JIB = NO (machine digit = 0)
JIB RIGHT/LEFT XXX% Displays jib swing switch direction & demand. NOTE: demand is
controlled by the pump pot
Displayed if JIB = SIDESWING (machine digit = 2)
JIB INLINE OP/CL Displays status of jib inline limit switch. Displayed on models
equipped with the Jib Stow System
JIB LIMIT OP/CL Displays status of jib right limit switch. Displayed on models
equipped with the Jib Stow System
JIB LIM OVRD OP/CL Displays status of jib limit override switch. Displayed on models
equipped with the Jib Stow System
PCV ON/OFF Displays status of Platform Control Valve. Displayed on models
equipped with Electronic Platform Leveling.
PUMP POT XXX% Displays pump pot demand. Not displayed if MODEL = 601
(machine digit = 4)
CREEP ACTIVE/NOT ACTIVE Displays pump pot creep switch status
CRP MODE ACTIVE/NOT ACT Displays creep mode status
Table 6-7. Machine Diagnostics Parameters
Diagnostics
Submenu
(Displayed on
Analyzer 1
st
Line)
Parameter (Displayed
on Analyzer 2
nd
Line)
Parameter Value
(Displayed on Analyzer 2
nd
Line)