JIB LIFT: ACCEL X.Xs Displays/adjusts jib lift acceleration 0.1 to 5.0 sec 1.5
DECEL X.Xs Displays/adjusts jib lift deceleration 0.1 to 3.0 sec 1
MIN UP XX% Displays/adjusts minimum jib up
speed. Same as Creep speed
0 to 65% 55
MAX UP XXX% Displays/adjusts maximum jib up
speed
0 to 100% 80 70-90
MIN DOWN XX% Displays/adjusts minimum jib down
speed. Same as Creep speed
0 to 65% 60
MAX DOWN XXX% Displays/adjusts maximum jib down
speed
0 to 100% 85 70-90
JIB SWING: ACCEL X.Xs Displays/adjusts jib swing accelera-
tion
0.1 to 5.0 sec 1.5
DECEL X.Xs Displays/adjusts jib swing decelera-
tion
0.1 to 3.0 sec 0.5
MIN LEFT XX% Displays/adjusts minimum jib left
speed. Same as Creep speed
0 to 65% 48
MAX LEFT XXX% Displays/adjusts maximum jib left
speed
0 to 100% 70 60-68 (180°)
MIN RIGHT XX% Displays/adjusts minimum jib right
speed. Same as Creep speed
0 to 65% 55
MAX RIGHT XXX% Displays/adjusts maximum jib right
speed
0 to 100% 70 60-68 (180°)
JIB TELESCOPE: ACCEL X.Xs Displays/adjusts jib tele acceleration 0.1 to 5.0 sec 1.5
DECEL X.Xs Displays/adjusts jib tele deceleration 0.1 to 3.0 sec 1
MIN IN XX% Displays/adjusts minimum jib tele in
speed. Same as Creep speed
0 to 65% 45
MAX IN XXX% Displays/adjusts maximum jib tele in
speed
0 to 100% 70 15-25 (see orientation)
MIN OUT XX% Displays/adjusts minimum jib right
speed. Same as Creep speed
0 to 65% 40
MAX OUT XXX% Displays/adjusts maximum jib right
speed
0 to 100% 70 15-25 (see orientation)
Table 6-4. Machine Personality Settings and Function Speeds
SUBMENU
(DISPLAYED ON
ANALYZER 1ST
LINE)
PARAMETER
(DISPLAYED ON ANALYZER
2
ND
LINE)
DESCRIPTION RANGE
DEFAULT
VALUES
TIME RANGE
(SEC)