Service Manual User guide
SECTION 6 - JLG CONTROL SYSTEM
6-14 – JLG Lift – 3121262
MAIN LIFT: ACCEL X.Xs Displays/adjusts main lift acceleration 0.1 to 5.0 sec 1
DECEL X.Xs Displays/adjusts main lift deceleration 0.1 to 3.0 sec 1
MIN UP XX% Displays/adjusts minimum main lift up
speed
0 to 60% 20
MAX UP XX% Displays/adjusts maximum main lift
up speed
0 to 100% 60 75-100 (see orientation)
CREEP UP XX% Displays/adjusts maximum main lift
up speed
0 to 65% 50
NOTE: used when creep switch on
pump pot is active
MIN DOWN XX% Displays/adjusts minimum main lift
down speed
0 to 60% 10
MAX DOWN XXX% Displays/adjusts maximum main lift
down speed
0 to 100% 60 85-110 (see orientation)
CREEP DOWN XX% Displays/adjusts maximum main lift
down speed
0 to 75% 45
NOTE: used when creep switch on
pump pot is active
SWING: ACCEL X.Xs Displays/adjusts swing acceleration 0.1 to 5.0 sec 2
DECEL X.Xs Displays/adjusts swing deceleration 0.1 to 3.0 sec 1.5
MIN LEFT XX% Displays/adjusts minimum swing left
speed
0 to 50% 40
MAX LEFT XXX% Displays/adjusts maximum swing left
speed
0 to 100% 65 115-125 (see orientation)
CREEP LEFT XX% Displays/adjusts maximum swing left
speed
0 to 65% 52
NOTE: used when creep switch on
pump pot is active
MIN RIGHT XX% Displays/adjusts minimum swing right
speed
0 to 50% 40
MAX RIGHT XXX% Displays/adjusts maximum swing
right speed
0 to 100% 60 115-125 (see orientation)
CREEP RIGHT XX% Displays/adjusts maximum swing
right speed
0 to 65% 47
NOTE: used when creep switch on
pump pot is active
Table 6-4. Machine Personality Settings and Function Speeds
SUBMENU
(DISPLAYED ON
ANALYZER 1ST
LINE)
PARAMETER
(DISPLAYED ON ANALYZER
2
ND
LINE)
DESCRIPTION RANGE
DEFAULT
VALUES
TIME RANGE
(SEC)