Service Manual User guide

SECTION 6 - JLG CONTROL SYSTEM
3121262 – JLG Lift – 6-13
6.2 MACHINE PERSONALITY SETTINGS AND
FUNCTION SPEEDS
NOTE: Personality settings can be adjusted within the
adjustment range in order to achieve optimum
machine performance.
Table 6-4. Machine Personality Settings and Function Speeds
SUBMENU
(DISPLAYED ON
ANALYZER 1ST
LINE)
PARAMETER
(DISPLAYED ON ANALYZER
2
ND
LINE)
DESCRIPTION RANGE
DEFAULT
VALUES
TIME RANGE
(SEC)
DRIVE: ACCEL X.Xs Displays/adjusts drive acceleration 0.1 to 5.0 sec 2
DECEL X.Xs Displays/adjusts drive deceleration 0.1 to 3.0 sec 1.3
MIN forward XX% Displays/adjusts minimum forward
drive speed
0 to 35% 1
MAX forward XXX% Displays/adjusts maximum forward
drive speed
0 to 100% 100 44-48 (see orientation)
MIN reverse XX% Displays/adjusts minimum reverse
drive speed
0 to 35% 1
MAX reverse XXX% Displays/adjusts maximum reverse
drive speed
0 to 100% 100 44-48 (see orientation)
ELEV. MAX XX% Displays/adjusts maximum drive
speed
0 to 50% 25 93-104 (see orientation)
NOTE: used when elevation cutout
switches are limiting maximum speed
CREEP MAX XX% Displays/adjusts maximum drive
speed
0 to 50% 35 79-87 (see orientation)
NOTE: used when creep switch on
pump pot is active
STEER: MAX SPEED XXX% Displays/adjusts maximum steer
speed.
0 to 100% 100