Service Manual User guide
SECTION 3 - CHASSIS & TURNTABLE
3-120 – JLG Lift – 3121262
3.21 GENERATOR
Every 250 hours
Every 250 hours of operation, check the drive belt for
proper tension.
Every 500 hours
Every 500 hours of operation, service the generator
brushes and slip rings. Hostile environments may require
more frequent service.
Every 500 hours of service, blow out the inside of the gen-
erator. If operating in a hostile environment, clean
monthly.
1/2 in.
(13 mm)