Service Manual

SECTION 6 - TROUBLESHOOTING
3121231 – JLG Lift – 6-19
Code 02 - Left PHP Bar - UP
Check For These Obvious Conditions First:
Obstruction under LEFT pot hole bar.
Obstruction around the actuator assembly at the base of the mast.
Code 03 - Right PHP Bar - UP
Check For These Obvious Conditions First:
Obstruction under RIGHT pot hole bar.
Obstruction around the actuator assembly at the base of the mast.
Table 6-7. Code 02 - Left PHP Bar - UP
STEP ACTION SPEC YES NO
CHECK THE FOLLOWING WITH THE PLATFORM ELEVATED 3 TO 4 FEET (1 TO 1.5m)
1. Go to the 20 pin molex connector at the Ground Control Module, back probe
to check for continuity of pin 10, (BLK # 8 wire ) with pin 2 0, ( ORG/RED 49-
1 wire). Is there continuity?
Replace Ground
Control Module
Go to Step 2
2. Check the actuator cables for adjustment or damage. Adjust or Replace Go to Step 3
3. Check the PHP limit switch(s) at both sides of the machine for damage,
adjustment and for continuity through switch to ground when bars are
down.
Replace, Adjust or
Repair Wiring
Table 6-8. Code 03 - Right PHP Bar - UP
STEP ACTION SPEC YES NO
CHECK THE FOLLOWING WITH THE PLATFORM ELEVATED 3 TO 4 FEET (1 TO 1.5m)
1. Go to the 20 pin molex connector at the Ground Control Module, back probe
to check for conti nuity of pi n 9, (BLK # 9 wi re) wi th p in 19, (O RG/RED 49-2
wire). Is there continuity?
Replace Ground
Control Module
Go to Step 2
2. Check the actuator cables for adjustment or damage. Adjust or Replace Go to Step 3
3. Check the PHP limit switch(s) at both sides of the machine for damage,
adjustment and for continuity through switch to ground when bars are
down.
Replace, Adjust or
Repair Wiring