Operator Manual User Manual

SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION
3-12 – JLG Lift – 3121230
Table 3-2. LCD Display - Operation Fault Conditions
FAULT
CODE
PLATFORM
LEDS
FLASHING
LCD SYMBOL SCREEN LCD TEXT SCREEN
FAULT DESCRIPTION/
MACHINE CONDITION
LOOK FOR THIS
——
Brakes Released
(DRIVE Disabled)
To Engage Brakes - Press Brake
Release Button on Ground Con-
trol Station
NONE
Charger AC Plugged In
DRIVE Disabled
Unplug Charger AC Power Cord
——
Obstruction Sensor System
(Platform Elevated)
LIFT DOWN Disabled
Obstruction Under Platform or
Sensor Defective
——
Programmable Security
Lock Password
Enter Code on PSL Keypad to
Power-Up Machine
22
Left PHP Bar UP
(Platform Elevated)
DRIVE and Lift UP Disabled
Lower Platform and Check the
Left Pot Hole Protection Bar
32
Right PHP Bar UP
(Platform Elevated)
DRIVE and Lift UP Disabled
Lower the Platform and Check
the Right Pot Hole Protection Bar
00000.0
00000.0
00000.0
02
02
00000.0
03
03
00000.0