Service Manual Manual

SECTION 6 - JLG CONTROL SYSTEM
3121142 – JLG Lift – 6-83
2211 22 11 FSW INTERLOCK TRIPPED The Footswitch was closed for
more then seven seconds.
- Can be reported during power-
up.
2212 22 12 DRIVE LOCKED - JOYSTICK MOVED BEFORE FOOTSWITCH A drive function was selected
with Footswitch open.
- Can be reported during power-
up.
2213 22 13 STEER LOCKED - SELECTED BEFORE FOOTSWITCH A steer function was selected
with Footswitch open.
2215 22 15 D/S JOY. OUT OF RANGE LOW The D/S Joystick reference volt-
age is low.
- Resistive joysticks, these faults
do not occur.
2216 22 16 D/S JOY. OUT OF RANGE HIGH The D/S Joystick reference volt-
age is > 8.1V.
- Resistive joysticks.
- If the reference voltage is > 7.7V
then the reference voltage is out
of tolerance of a short to battery
has occurred.
2217 22 17 D/S JOY. CENTER TAP BAD The D/S Joystick center tap volt-
age is < 3.08V or > 3.83V.
- Resistive joysticks.
- There is a +/- .1V range. around
these values due to resistor toler-
ances
2218 22 18 L/S JOY. OUT OF RANGE LOW The L/S Joystick reference volt-
age is low.
- Resistive joysticks, these faults
do not occur.
2219 22 19 L/S JOY. OUT OF RANGE HIGH The L/S Joystick reference volt-
age is > 8.1V.
- Resistive joysticks.
- If the reference voltage is > 7.7V
then the reference voltage is out
of tolerance of a short to battery
has occurred.
2220 22 20 L/S JOY. CENTER TAP BAD The L/S Joystick center tap volt-
age is < 3.08V or > 3.83V.
- Resistive joysticks.
- There is a +/- .1V range. around
these values due to resistor toler-
ances
2221 22 21 LIFT/SWING LOCKED - JOYSTICK MOVED BEFORE FOOTSWITCH A lift / swing function was
selected with Footswitch open.
2222 22 22 WAITING FOR FSW TO BE OPEN The Footswitch was closed dur-
ing Platform selection.
- Can be reported during power-
up.
2223 22 23 FUNCTION SWITCHES LOCKED - SELECTED BEFORE ENABLE A boom function was selected
with Footswitch open.
2224 22 24 FOOTSWITCH SELECTED BEFORE START The Footswitch was closed dur-
ing engine start.
230 23 0 <<< GROUND CONTROLS >>>
234 23 4 FUNCTION SWITCHES FAULTY - CHECK DIAGNOSTICS/BOOM A boom function has both direc-
tions selected together.
235 23 5 FUNCTION SWITCHES LOCKED - SELECTED BEFORE AUX POWER A boom function was selected
before aux power.
Table 6-6. Diagnostic Trouble Code Chart
DTC
Flash
Code
Sequence
Fault Message Fault Description Check