Service Manual Manual

SECTION 6 - JLG CONTROL SYSTEM
6-26 – JLG Lift – 3121142
GROUND
MODE:
U. LIFT UP XXX% Displays/adjusts fixed main lift up sp ee d 0 to 100% 60 6 0
U. LIFT DN XXX% Displays/adjusts main lift down speed 0 to 100% 60 60
SWING XXX% Displays/adjusts fixed swing speed 0 to 100% 60 60
BASKET LVL XXX% Displays/adjusts fixed basket level speed 0 to 100% 75 75
BASKET ROT XXX% Displays/adjusts fixed basket rotate speed 0 to 100% 75 75
MAIN TELE XXX% Displays/adjusts fixed main telescope speed 0 to 100% 60 60
TOWER TELE XXX% Displays/adjusts fixed tower telescope speed
Not displayed if TOWER TELE=NO
0 to 100% 100 100
T. LIFT UP XXX% Displays/adjusts fixed tower lift up speed
Not displayed if TOWER LIFT=NO
0 to 100% 100 100
T. LIFT DN XXX% Displays/adjusts fixed tower lift down speed
Not displayed if TOWER LIFT=NO
0 to 100% 100 100
JIB (U/D) XXX% Displays/adjusts jib lift speed
Not displayed if JIB = 0
0 to 100% 60 60
JIB (L/R) XXX% Displays/adjusts jib swing speed
Displayed if JIB = 2
0 to 100% 70 70
GEN SET/WELDER: ENGINE XXXX RPM Control generator/welder RPM. Not displayed if
GEN SET/WELDER = 0
1200-2800 1800 1800
4150453-F
Table 6-3. Personality Ranges/Defaults
SUBMENU
(DISPLAYED ON
ANALYZER 1ST LINE)
PARAMETER
(DISPLAYED ON ANALYZER 2
ND
LINE)
DESCRIPTION RANGE
DEFAULT VALUES
TIME RANGE (SEC) (SEE
SECTION 6.10 FOR
MACHINE ORIENTATION
WHEN SETTING SPEEDS)
1200 1350 1200S 1350S