SECTION 3 - CHASSIS & TURNTABLE
3121142 – JLG Lift – 3-173
DTC 1615- Microprocessor Failure - A/D
Engine Control Module
Check Condition- Key on
Fault Condition- Internal microprocessor error
MIL- On until code is cleared by technician
Adaptive- Disabled for the remainder of the key-on cycle
Closed Loop- Enabled
Power Derate (level 2 until fault is cleared manually)
The ECM has checks that must be satisfied each time an
instruction is executed. Several different things can happen
within the microprocessor that will cause this fault. The ECM
will reset itself in the event this fault is set, and the MIL will be
on until the code is cleared. This fault should be erased after
diagnosis by removing battery power. It will not self-erase.
During this active fault, Power Derate (level 2) will be enforced.
When this is enforced, maximum throttle position will be 20%.
This is enforced until the fault is manually cleared.
RAM
ECM
Microprocessor