SECTION 3 - CHASSIS & TURNTABLE
3121142 – JLG Lift – 3-149
DTC 219- RPM Higher Than Max Allowed Governed
Speed
Max Govern Speed Override- Crankshaft Position Sensor
Check Condition-Engine Running
Fault Condition-Engine speed greater than the max gover-
nor override speed as defined in the diagnostic calibration
Corrective Action(s): Sound audible warning or illuminate
secondary warning lamp, reduce throttle to limit speed.
Recommend closed loop and adaptive learn fueling correc-
tion remains active during fault.
Non-emissions related fault
This fault will set anytime the engine RPM exceeds the limit set
in the diagnostic calibration for the latch time or more. This
speed overrides any higher max governor speeds pro-
grammed by the user. This fault is designed to help prevent
engine or equipment damage.
The throttle will be lowered in order to govern the engine to
the speed set in the diagnostic calibration.
DTC 219- RPM Higher Than Max Allowed Governed Speed
(continued)
Diagnostic Aids
NOTE: If any other DTCs are present, diagnose those first.
Ensure that no programmed governor speeds exceed the
limit set in the diagnostic calibration for Max Gov Override
Speed
Check mechanical operation of the throttle actuator
PINK/WHITE
4
3
5
1
2
TAN/ORANGE
GREEN/RED
PURPLE/BLUE
BLACK/GREEN