Service Manual Instruction Manual

SECTION 6 - JLG CONTROL SYSTEM
3121171 – JLG Lift – 6-97
9910 99 10 FUNCTIONS LOCKED OUT - PLATFORM MODULE SOFTWARE VERSION
IMPROPER
The Platform Module software
version is not compatible with
the rest of the system.
9911 99 FUNCTIONS LOCKED OUT - LSS MODULE SOFTWARE VERSION IMPROPER
9914 99 14 PLATFORM MODULE SOFTWARE UPDATE REQUIRED The Platform Module software
requires an updated.
9915 99 15 CHASSIS TILT SENSOR NOT GAIN CALIBRATED The Chassis Tilt Sensor gain cali-
bration has been lost.
9916 99 16 CHASSIS TILT SENSOR GAIN OUT OF RANGE The Chassis Tilt Sensor gain cali-
bration has become corrupted.
9917 99 17 HIGH RESOLUTION A2D FAILURE - INTERRUPT LOST The Platform Module has
reported that its ADS1213 chip
has stopped asserting its inter-
rupt.
9918 99 18 HIGH RESOLUTION A2D FAILURE - REINIT LIMIT The Platform Module has
reported that its ADS1213 chip
had to be reset 3 or more times.
9919 99 19 GROUND SENSOR REF VOLTAGE OUT OF RANGE The Ground Module has
reported that its sensor refer-
ence voltage is outside accept-
able range.
- Not reported during power-up.
9920 99 20 PLATFORM SENSOR REF VOLTAGE OUT OF RANGE The Platform Module has
reported that its sensor refer-
ence voltage is outside accept-
able range.
- Not reported during power-up.
9921 99 21 GROUND MODULE FAILURE - HIGH SIDE DRIVER CUTOUT FAULTY The Ground Module has
reported that its high side driver
cutout failed.
9922 99 22 PLATFORM MODULE FAILURE - HWFS CODE 1 The Platform Module has
re por t ed th at th e V( Lo w) FE T
has failed.
9923 99 23 GROUND MODULE FAILURE - HWFS CODE 1 The Ground Module has
re por t ed th at th e V( Lo w) FE T
has failed.
9924 99 FUNCTIONS LOCKED OUT - MACHINE NOT CONFIGURED
9925 99 25 FUNCTIONS LOCKED OUT - CHASSIS MODULE SOFTWARE VERSION
IMPROPER
The Chassis Module software
version is not compatible with
the rest of the system.
9926 99 26 FUNCTIONS LOCKED OUT - BLAM MODULE SOFTWARE VERSION IMPROPER The BLAM software version is
not compatible with the rest of
the system.
9927 99 27 GROUND MODULE CONSTANT DATA UPDATE REQUIRED The Ground Module constant
data requires an updated.
Table 6-6. Diagnostic Trouble Code Chart
DTC
Flash
Code
Sequence
Fault Message Fault Description Check